OPERATING INSTRUCTIONS
AIR INLET CONTROL
The Arada Farringdon 12kw stove air inlet control.
The primary air inlet provides the main air supply to the
fuel and the air wash system through the control slider
located under fire door on the Left side. Placed fully to
the LEFT is Low air, and to the RIGHT is High air.
The air wash system, so called because its pre-heated
high speed air, washes across the inner face of the door
glass, keeping it clear. This also provides an over
draught to the fuel bed, for combustion of the wood fuel.
PRIMARY AIR
Air enters the appliance through the control at the
bottom of the fire door. The Arada Farringdon has a
single control slider sliding left to right.
See Fig. 10. & 11. below
Note:
The air supply does not fully close intentionally
Fully Open Position (Lever In RH Position) Minimum Closed Position (Lever In LH Position)
The exact position of the air control will vary
according to installation factors and some
experimentation will be required to acquire the
optimum position for burning
The primary air control (Left) should be used to
vary the burn rate. 3/4 open will produce
approximately 12 kwh for a 3.8kg load (1 hour
burn time to refuelling) dependant on fuel quality
and moisture content.
Operation at continuously low burn rates will
increase the production of tar and other residues
building up in the flue and chimney and should be
avoided.
Fig. 10. Fig. 11.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arada Farringdon 12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arada Farringdon 12 in the language / languages: English as an attachment in your email.

The manual is 3.17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Arada Farringdon 12

Arada Farringdon 12 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info