2.8 - SPILLAGE
Check for clearance of combustion products.
Close all doors and windows in the room containing appliance.
Turn on appliance and turn to high, leave running for 5 minutes and insert a lighted taper or smoke match into
the flue diverter at the rear of the appliance.
All the smoke must be drawn into the appliance.
If spillage occurs, allow a further 10 minutes and retest.
Should spillage occur, seek expert advice.
If an extractor fan is situated in the room, the test should be carried out with the fan running, if there is a
connected room with an extractor fan the test should be repeated with the fan running and any
interconnecting doors open.
2.9 - CUSTOMER EDUCATION
Hand these instructions to user.
Advise the user until they are fully educated on the use of the stove and the controls.
Explain regarding the thermal cut off feature.
Advise if this system repeatedly shuts off specialist advice must be consulted.
Advise that if the fire goes off for any reason do not re-light for 3 minutes.
Advise the stove may give off a slight smell due to the newness and any odours will go after a few hours of
use.
Advise that the stove must not be used with the glass panel damaged or broken or missing.
Advise that no materials like washing, may not be draped over the stove.
Recommend regular servicing at least annually.
Recommend no extra fuel pieces are added and only authorized spares used.
3.0 - SERVICING INSTRUCTIONS
The stove is fitted with a spillage monitoring system consisting of a thermal switch this system is non
adjustable and must not be bypassed or put out of action if any parts are replaced it must be with the original
manufacturers parts used.
1. Servicing must be carried out regularly and only by a qualified person, ensure the fire is turned off and cold
(minimum service must be carried out annually)
2. Open the stove door by unscrewing the handle on the left fully and remove the door can now be opened or
even lifted off its hinges then the screws holding the glass can be removed and the glass panel removed.
3. Remove the ceramics carefully.
4. Remove any debris from the burner if necessary vacuum, also clean the pilot or vacuum.
5. If necessary replace pilot (for extended warranty) by removing burner and disconnect gas supply 4 screws
can be removed and burner tray removed the thermal cut off switch will have to be disconnected at the rear of
the fire to allow the tray to be removed it has to be lifted up on the right hand side and carefully twisted out
6. Replace burner tray and reconnect thermal switch the appliance will not work if this is not done and then
replace in reverse order replace glass and stove door.
7. Check the supply pressure and test for spillage
8. The flue will need sweeping periodically for safe use of the appliance.
3.1 REPLACEMENT PARTS
Genuine replacement spare parts can be
obtained from www.aradastovesandspares.com
or your Arada dealer.
Please note, that fitting non-official Arada parts to
your stove will invalidate the guarantee.
BK 710 Page 18
Pilot Assembly ERTA-PG-82-10
Thermal Switch TSC-30112010AFV
Thermal Switch Wires TTB Wires
Fuel Logs
Injector STEREOMATIC 500
Handset TESC Handset
Valve TESC01 RF868-15
ECOBURN PLUS GAS — INSTALLATION & SERVICE
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arada Ecoburn Plus Gas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arada Ecoburn Plus Gas in the language / languages: English as an attachment in your email.

The manual is 8.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info