3-5 Continuity Check by Internal Sounder
1. Connect the red test lead to the ºC VΩHz terminal and the other (black) test lead to the COM terminal.
2. Set the rotary function selector to Ω : position.
3. Connect the test leads to the circuit to be measured. The internal sounder will operate if the resistance of the
circuit measured is lower than 30Ω approximately.
3-6 Diode Check
1. Set the rotary switch at Ω : position.
2. Connect black test lead to COM terminal and red lead to ºC VΩHz input terminal.
3. Connect test leads to the diode normally the forward voltage drop of good silicon diode is shown between
0. 400V and 0.900V. If the diode under test is defective. 0.000 (short circuit) or OL (non-conductance) is
displayed. During check, the diode under test is defective, if 0.000 or other values are displayed.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Appa 99 II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Appa 99 II in the language / languages: English as an attachment in your email.

The manual is 0,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info