Note : 1. With zero calibrated before measurement.
2* 4V range specifies readings above 10% of full scale of range.
3. Amp ranges specify reading <90% of full scale of range.
4. In the noise generating field, may affect intervals.
(12) Auto Power Off (APO)
The APO annunciator on the LCD panel indicates that the meter is working in the Auto Power Off mode. If the
meter idles for more than 30 minutes, the meter automatically turns the power off. When this happens, the
state (non-logic measurement) of the meter is stored. The meter can be turned back on by pushing any switch
except back light switch or changing the rotary switch. If the meter is Re-Powered by pushing any switch,
the LCD displays the stored value. Pressing the Hold switch disables the hold state. The meter will produce a
periodic alarm 15 seconds before automatically turning power off , any key press or rotary change will reset
the Auto-Power-Off delay of 30 minutes.
(13) Disable Auto Power Off
In order to disable Auto Power Off function, power up the meter whilst pressing any of the function switches
other than the Hold or BLUE switches.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Appa 99 II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Appa 99 II in the language / languages: English as an attachment in your email.

The manual is 0,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info