3-2 Voltage Measurements
1. Connect the red test lead to the V Hz input terminal and the other (black) test lead to the COM terminal.
2. Set the rotary function to the V ' position.
3. Measurement of AC voltage can be performed by pushing the BLUE key switch.
#
WARNING
TO AVOID ELECTRICAL SHOCK, HAZARD OR DAMAGE TO METER, DO NOT A ATTEMPT TO
MEASURE VOLTAGE THAT MIGHT EXCEED 1000V ms. DO NOT APPLY MORE THAN 1000V rms
BETWEEN THE COMMON INPUT TERMINAL AND EARTH GROUND.
NOTICE
UNSTABLE DISPLAY MAY OCCUR ESPECIALLY AT 400mV RANGE, EVEN THOUGH YOU DONT
PUT TEST LEADS INTO INPUT TERMINALS. IN THIS CASE, IF AN ERRONEOUS READING IS
SUSPECTED, SHORT THE V Hz TERMINAL AND THE COM TERMINAL, AND MAKE SURE
THE DISPLAY IS AT ZERO.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Appa 98 II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Appa 98 II in the language / languages: English as an attachment in your email.

The manual is 0,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info