729429
19
Zoom out
Zoom in
Previous page
1/24
Next page
18
3-2 AC/DC Current Measurement
1. Turning the rotary switch at “A” or “A“ position.
2. Open clamp by pressing trigger on left side of meter.
3. Position clamp around wire or conductor and release clamp trigger smoothly , do not release quickly, make sure
that the clamp is entirely closed. Position the conductors at the center of the clamp jaws for accurate measure-
ment . The clamp must be positioned around only one conductors of a circuit .
If the clamp is placed around two or more current-carrying conductors , the meter reading will be FALSE.
4. For DC measurement , the reading is positive value when the current flows from the upper side to the lower
side of the instrument as Figure 2.
5. For accuracy measurement on DCA mode follow the procedure below
(i) Position clamp around wire or conductor and release clamp trigger smoothly, do not release quickly,
make sure that the wire or conductor is at the center of the clamp.
(ii) Remove the wire or conductor from the clamp.
(iii) Press the ZERO A button to zero the reading, effective in DCA mode only.
(iv) Repeat (i).
(v) The positive reading measurement can get better accuracy in DCA mode.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Appa 36RII at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Appa 36RII in the language / languages: English as an attachment in your email.

The manual is 0,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info