729425
25
Zoom out
Zoom in
Previous page
1/32
Next page
24
NOTICE
UNSTABLE DISPLAY MAY OCCUR ESPECIALLY AT 400mV RANGE, EVEN THOUGH YOU DONT PUT
TESTED LEADS INTO INPUT TERMINALS. IN THIS CASE, IF AN ERRONEOUS READING IS SUSPECTED,
SHORT THE VΩHz TERMINAL AND THE COM TERMINAL, AND MAKE SURE THE ZERO DISPLAY.
3-3 Current Measurements
1. Connect the red test lead to mA terminal and the other (black) test lead to COM terminal, or use the A and COM
terminal in the 10A range.
2. Set function selector rotary switch to mA or A .
3. Measurement of AC current can be performed by pushing the BLUE switch.
4. Connect the test leads to the circuit to be measured.
3-4 Resistance Measurement
1. Connect the red test lead to the VΩHz terminal and the other (black) test lead to the COM terminal.
2. Set the rotary function selector to Ω : position to measure the resistance.
3. For correct reading, ensure that the device being tested contains no voltage.
4. Connect the test leads across the resistor to be measured. In order to ensure the best accuracy in measurement of low
resistance, short the test leads before measurement and memorize the test probe resistance in mind. This is necessary
to subtract for the resistance of the test leads themselves.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Appa 103N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Appa 103N in the language / languages: English as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info