79NetBotz Appliance User’s Guide
Managing your appliance using a dial-In PPP connection
When dial-in support is enabled, the appliance places the external modem in auto-answer mode. This
allows you to initiate a dial-in connection to the appliance through the external modem. To authenticate a
PPP connection, you must provide a user ID and password for a user account with Administrator access.
Once the PPP connection is established, you can access the appliance using the IP address
192.168.254.1.
Note: IP traffic is not routed through the appliance, so you cannot use the appliance PPP
connection to access other devices or systems on the same Ethernet network as the appliance,
if the appliance is connected to an Ethernet network as well as a modem.
PPP performance considerations
PPP/Modem connections are slower than Ethernet and wireless network connections. Using SSL to
communicate with an appliance over a PPP/Modem link slows communications further. If the appliance
attempts to send too much data over a PPP connection, some events never get delivered or get delivered
long after they occur.
When monitoring or managing an appliance connected to your network using only a PPP/Modem
connection, some functions are unavailable and performance is limited. The use of NetBotz Surveillance
with InfraStruXure Central on appliances connected to the network using PPP is not supported.
Performance can become worse if the PPP connection is lower than 25000 V42bis or the appliance is
configured to send large files such as images and audio. Some performance issues include:
Loading the Alerts View: If the appliance has a large number of active or resolved alerts stored
on the appliance, an External Storage System, or the NAS, loading the Alerts View may take a
long time, or the Alerts view may fail to load. If this is an issue, limit the number of alerts by
clearing the Include “Returned to Normal” Alerts check box. Once you have successfully
loaded the Alerts View, set the Refresh Interval value to None. If you do not do this, Advanced
View periodically reloads the Alerts View. This impacts the amount of data that the appliance can
send over the PPP connection and could prevent you from loading alerts or other data.
Streaming Audio: Streaming audio does not perform well over PPP/Modem connections. If you
enable streaming audio, you may encounter large gaps in the audio stream.
Access by Multiple Clients: If more than one client is accessing an appliance over a PPP/Modem
connection, performance is degraded.
Delivering Higher Resolution Images, Setting High Frame Rates: If your appliance generates
alert notifications that include large amounts of image data, delivery of the notifications is delayed
due to the slow PPP connection. If too many notifications are delayed, some notifications will not
be sent. Appliances communicating using PPP should have their Camera Pod Capture settings and
Cameras View frame rates set to the lowest acceptable values: 320x240; 1 frame every 10 seconds
respectively.
Viewing Alert Captures: Loading and viewing alerts that include a large number of image
captures or audio clips can take a long time. If the alert includes audio, the audio may not load
properly and may not be synchronized with the images. Loading alerts that include many image
captures in Basic View over a PPP/modem connection can be slow and can cause the browser to
become unstable. Therefore, when using a PPP connection to view alerts, use Advanced View.
Performing Multiple Alert Actions Simultaneously: Appliances communicating over a PPP
connection should not be configured to perform more than two alert actions simultaneously,
particularly if the alert actions include sending image captures or if any of the actions use the Send
87


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Apc nbwl0455 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Apc nbwl0455 in the language / languages: English as an attachment in your email.

The manual is 1,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info