6)CONDENSATE.
PAC60BX
In operation, the room unit is constantly
condensing water vapour out of the
atmosphere (reducing relative humidity).
This water has to be drained away. Two
automatic condensate pumps are fitted
inside the PAC60BX room unit. The flexible
hose outlet from the condensate pumps
runs to the outside inside the cable bundle.
The condensate is deposited in the base of
the heat exchanger, considerable re-
evaporation of this water takes place on the
warm air stream passing through and
around the heat exchanger, but please
remember that there will also be a degree
of dripping through the base of the heat
exchanger.
HAVE GREAT REGARD FOR THIS
CHARACTERISTIC WHEN
POSITIONING THE EXTERNAL HEAT
EXCHANGER.
The flexible water pipes should be routed
so as to avoid any unnecessary restrictions
to the flow of water inside.
7) MACHINE LINK-UP FOR PAC60BX/
Ensure the mains supply lead to the room
unit is disconnected. A 15m line set to
connect all services between the room unit
and the external heat exchanger will have
been supplied. The water pipe connections
are by means of "quick connect couplers".
These are simple 'push-on" connectors
which, when disconnected (after pulling
back sprung loaded locking ring), re-seal the
water system on either side. The complete
system will have been filled with the
necessary amount of water/antifreeze prior
to its arrival on site. A water
proof 5 pin quick
connect electrical coupler (push fit with
screw lock ring, hand tight only), and
condensate drain pipe coupler 6mm clear
polythene (push fit), should also be
connected. Having made the couplings, the
system is operational immediately.
FEMALE MALE
POWER
CONNECTION
WATER IN/OUT
CONNECTIONS
CONDENSATE
DRAIN
CONNECTION
HEAT EXCHANGER CONNECTIONS
MAINS IN
OUT TO HEX
PAC CONNECTIONS
WATER
IN/OUT
CONDENSATE
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Andrews PAC60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Andrews PAC60 in the language / languages: English as an attachment in your email.

The manual is 0,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info