Measurements
Note: The UB-543, once used, will provide an inflation appropriate to the user.
1. Wrap the cuff around your wrist. Sit comfortably with the cuff at the same level
as your heart and relax.
2. Press the
START button. All of the display segments are displayed.
3. Select a user from user and user using the
SET
button immediately.
Adjust and keep the height of the cuff (with blue light) to the same level as your
heart using the C.P.G. indicator.
Note
: If you do not use user selection, wait for the inflation for several seconds.
If you do not use the C.P.G. function, the C.P.G. indicator is not displayed.
4. Zero (0) is displayed blinking briefly. Then the display changes, as
measurement begins. The cuff starts to inflate. It is normal for the cuff
to feel very tight. The measurement starts automatically when
inflation starts, and the
(heart mark) blinks.
Note: If you wish to stop inflation at any time, press the
START button again.
5. When the measurement is complete, the device displays readings
( of the systolic and diastolic pressure readings, pulse rate, WHO
classification, I.H.B. symbol and C.P.G. indicator). While readings are
displayed, the date and time are displayed alternately. The cuff
exhausts the remaining air and completely deflates automatically.
Note: If you do not want to store new readings in memory, press the
button while readings are displayed.
6. Press the
START button again to turn the device off. Remove the cuff.
Notes
: The device is provided with an automatic power shut-off function.
Allow at least one minute between measurements on the same person.
Use
r
or use
r
:
SET
button
The C.P.G. indicator:
Orange Blue Orange
LOW LEVEL HIGH
Zero display
Inflation is started
Inflating and
Measurement in progress
Systolic pressure
Diastolic pressure
WHO classification
I.H.B. symbol
Pulse rate
The C.P.G. indicator
All segments
At heart level
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AnD UB -543 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AnD UB -543 in the language / languages: English as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info