Water Filter
System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge
Specifications
Service Flow Rate (Maximum).............................................0.78 GPM (2.9 L/min)
Rated Service Life 750 (Maximum) ...................................750 gallons/2838 liters
Maximum Operating Temperature .....................................100° F/38° C
Minimum Pressure Requirement........................................35 psi/241 kPA
Minimum Operating Temperature......................................33° F/ C
Maximum Operating Pressure.............................................120 psi /827 kPA
Performance Data
Timely replacement of filter cartridge is essential for
performance satisfaction from this filtration system.
Please refer to the applic
able section of your Use &
Care Guide for general operation, maintenance
requirements and troubleshooting.
This system has been tested according to ANSI/NSF 42
and 53 for reduction of the substance listed above. The
concentration of the indicated substances in water
entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving
the system, as specified in A
N
S
I
/NSF 42 and 53.
* Tested using a flow rate of 0.78 GPM; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of
68° ± 5° F (20° ± 3° C) under standard laboratory conditions, however, actual
performance may vary. Health Claim Performance tested and certified by NSF
International
** Measurement in Particles /ml. Particles used were 0.5 - 1 microns
*** NTU - Nephelometric Turbidity units
General Use Conditions
Read this Performance Data Sheet and compare the
capabilities of this unit with your actual water
treatment needs.
D
O NOT use this product where water is micro-
biologically unsafe or of unknown quality without
adequate disinfection before or after the system.
System certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK
FOR COMPLIANCE WITH THE STATE AND LOCAL
LAWS AN
D R
E
G
ULATIONS.
TM
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Taste & Odor
Mechanical Filtration Unit
P
articulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane, Mercury &
Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
Tested and certified by NSF International against ANSI/NSF Standards 42 & 53
in models 750 for the reduction of:
Parameter
C
hlorine
T
& O
Particulate**
U
SEPA
MCL
S
tandard No. 42: Aesthetic Effects
I
nfluent
Challenge Concentration
2
.0 mg/L ± 10%
at least 10,000 particles/ml
I
nfluent
Average
1
.88 mg/L
5,700,000 #/ml
Average
<
0.05 mg/L
30,583 #/ml
Maximum
0
.06 mg/L
69,000 #/ml
Average
>
97.26%
99.52%
Minimum
9
6.84%
98.94%
M
in. Required
Reduction
5
0%
85%
Effluent % Reduction
Parameter
Turbidity
Cysts
Asbestos
Lead at pH 6.5
Lead at pH 8.5
Mercury at pH 6.5
Mercury at pH 8.5
Lindane
Toxaphene
Atrazine
USEPA
MCL
1 NTU**
99.5% Reduction
99% Reduction
0.015 mg/L
0.015 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
S
tandard No. 53: Health Effects
Influent
Challenge Concentration
11 ± 1 NTU***
Minimum 50,000/L
10
7
10
8
fibers/L; fibers >10 micrometers in length
0.15 mg/L ± 10%
0.15 mg/L ± 10%
.006 mg/L ± 10%
.006 mg/L ± 10%
0.002 mg/L ± 10%
0.015 mg/L ± 10%
0.009 mg/L ± 10%
Influent
Average
10.73 NTU
220,000 #/L
155 MF/L
0.153 mg/L
0.150 mg/L
0.006 mg/L
0.006 mg/L
0.002 mg/L
0.015 mg/L
.00873 mg/L
Average
0.36 NTU
<1
<1
<.001
<.001
0.00026
0.0008
0.000025
<0.001
<0.002
Maximum
.049 NTU
<1
<1
<.001
<.001
0.0005
0.0015
0.00007
<0.001
<0.002
Average
97.09%
>99.99%
>99.99%
>99.35%
>99.35%
98.72%
98.72%
98.72%
92.97%
76.99%
Minimum
95.20%
>99.99%
>99.99%
>99.35%
>99.35%
90.91%
75.93%
96.50%
91.67%
75.31%
Min. Required
Reduction
0.5 NTU
>99.95%
99%
0.10 mg/L
0.10 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
Effluent % Reduction
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Amana AC 2224 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Amana AC 2224 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 71,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info