MACHINE OPERATION
Picking Up Dry Substances
Before picking up dry substances, the bag-type filter
should always be installed in the tank. It is then easy
to dispose of the material picked up and the service life
of the main filter element is significantly increased. Dry
cleaning without bag-type filter is also possible.
WARNING: Inflammable substances must not
be picked up with the machine!
After picking up liquids, the filter element is damp.
Damp filter elements can clog more quickly when dry
substances are picked up. For this reason, the filter
element should be dried or replaced before picking up
any dry substances.
Picking Up Liquids
Before picking up liquids, the bag-type filter must
always be removed from the tank.
WARNING: Inflammable liquids must not be
picked up with the machine!
If foaming is observed, stop work immediately and
empty the tank.
Switching On The Machine (SQ 10/15/17 & aero 5)
Turn the switch to position "I" (Figure 6).
Switching On The Machine (aero 7 AS/E)
Two operating modes are possible.
1. Switch position "I":
The machine motor starts immediately.
2. Switch position "auto":
The machine motor starts only when the tool
connected to the appliance plug socket is switched
on (Figure 7).
CAUTION: Before turning the switch to position
"auto", ensure that the tool connected to the
appliance plug socket is switched off.
The motor speed and thus the suction power can be
varied at the suction force regulator. This permits a
precise adaptation to different substances to be picked
up (Figure 7).
After Finishing Work
1. Switch off the machine and pull the plug of the
power cord out of the plug socket.
2. Wind up the power cord around the handle (Figure
8).
Figure 6
Figure 7
Figure 8
Page -8- WAP TECHNOLOGY Wet/Dry Vacuums Operator's Manual
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alto-WAP SQ 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alto-WAP SQ 15 in the language / languages: English as an attachment in your email.

The manual is 0,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Alto-WAP SQ 15

Alto-WAP SQ 15 User Manual - English, French - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info