Technische Änderungen vorbehalten | 83059600gDE – Originalbetriebsanleitung | ait-deutschland GmbH
Aufstellungsplan, Flächenfundament
865
755
335
485
90
60
10
10
10
10
845
735
Y
11
12
GK
≥50
≥50
≥100
11
13
14
OKF
OKB
Y(1:5)
16
17
18
18
13
13
Z
Das Fundament darf keinen Körperschallkontakt zum
Gebäude haben.
OKF Oberkante Fundament
GK Gerätekontur
OKB Oberkante Boden
16 Leerrohr für Bus-Kabel
17 Leerrohr für Elektrokabel
18 Heizwasser Vor- und Rücklaufleitung
Legende: D819497-2
Technische Änderungen vorbehalten.
Alle Maße in mm.
A Vorderansicht
C Draufsicht
Y Detailansicht Y
Z Detailansicht Bodenbefestigung
11 Fundament (frostsicher)
12 Hydraulische Verbindungsleitung
13 Leerrohr DN150/160 (bauseits)
14 Kondensatablaufrohr DN100/110 (bauseits)
A
C
8
7
6
5
4
3
2
1
---
www.ait-deutschland.eu
D - 95359 Kasendorf
Industriestraße 3
ait-deutschland GmbH
2
5
Ers. d.
Ers. f.
A
B
C
D
E
F
F
E
D
C
B
A
4
3
2
1
Benennung
Zust.
Änderungstext
Datum
Von
Blatt
von
Werkstoff
Gewicht
-
Maßstab
1:15
1:5
Det. Maßstab
Datum
Name
Erstellt
Gepr.
Norm.
toleranz
Allgemein-
Oberflächen
ArtikelNr.
Schutzvermerk ISO 16016 beachten
DIN ISO 2768 -cL
-
NG
25.10.2017
PEP 011/2017
-
819497
---
Flächenfundament LWAV 8-12kW
25.10.2017
Gruosso
11.10.2017
Gruosso
Legende: D819497-2
Technische Änderungen vorbehalten.
Alle Maße in mm.
A Vorderansicht OKF Oberkante Fundament
C Draufsicht GK Gerätekontur
Y Detailansicht Y OKB Oberkante Boden
Z Detailansicht Bodenbefestigung
11 Fundament (frostsicher)
12 Hydraulische Verbindungsleitung
13 Leerrohr DN150/160 (bauseits)
14 Kondensatablaufrohr DN100/110 (bauseits)
16 Leerrohr für Buskabel
17 Leerrohr für Elektrokabel
18 Heizwasser Vor- und Rücklaufleitung
DasFundamentdarfkeinenKörperschallkontaktzum
Gebäude haben.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alpha innotec LWAV 122R3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alpha innotec LWAV 122R3 in the language / languages: German as an attachment in your email.

The manual is 3,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info