684788
65
Zoom out
Zoom in
Previous page
1/68
Next page
65
Technische Änderungen vorbehalten | 83054400eDE – Originalbetriebsanleitung | ait-deutschland GmbH
LW 310
a
b
Legende:
Betriebsmittel
A1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
TWE
TWA
TRL
TVL
THG
TA
TBW
RVF
CW
TB1
-X4
-R7
DE
Funktion
Reglerplatine; Achtung: I-max = 6,3A/230VAC
Falls eingebaut: Wärmequelle Eintrittsfühler
Falls eingebaut: Wärmequelle Austrittsfühler
Rücklauffühler
Vorlauffühler
Heissgasfühler
Aussenfühler
Brauchwasserfühler/thermostat
Zubehör: Raumfernversteller
Codier Widerstand
Fühler Mischkreis 1
817340b
-X4
-R8
-X4
-R9
1150 Ohm
-X4
-R11
-X5
-R2
-X5
-R3
-X5
-R4
-X5
-R5
-X5
-R6
-X5
-R10
123 45678
12 8
A
B
C
D
E
F
A
B
C
D
E
F
Blatt
Bl.
3
3
3 4567
AIT
817340
Stromlaufplan
ait-deutschland GmbH
ÄM008/2011
ÄM066/2015
14.03.2011
17.12.2015
AP
AP
AP
TA
TA
GND
TBW
TBW
GND
RFV
RFV
GND
TB1
TB1
GND
TWE
TWE
GND
TWA
TWA
GND
TRL
TRL
GND
TVL
TVL
GND
THG
THG
GND
CW
CW
GND
-A1
Änderung Datum
Datum
Bearbeiter
Geprüft
NormName
02.12.2015
Pfleger
R.
Stromlaufplan 3/3 LW 310(L)
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alpha innotec LW 140 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alpha innotec LW 140 in the language / languages: German as an attachment in your email.

The manual is 7,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info