Chapter 3: Port Configuration
66
Mode -This parameter i Indicates the speed and duplex mode
settings for the port. You can use this parameter to set the speed
and duplex mode of a port. The possible settings are:
Ignore -This parameter i Indicates that the All setting does not
apply to the Mode field. In other words, each port is set
individually.
Auto -This parameter i Indicates the port is using Auto-
Negotiation to set the operating speed and duplex mode. The
actual operating speed and duplex mode of the port are
displayed in parentheses (for example, “1000F” for 1000 Mbps
full duplex mode) after a port establishes a link with an end
node.
Auto (1000F) -This parameter i Indicates the port is configured
for 1000Mbps operation in Auto-Negotiation mode.
1000/Full -This parameter i Indicates the port is configured for
1000Mbps operation in full-duplex mode.
100/Full -This parameter i Indicates the port is configured for
100Mbps operation in full-duplex mode.
10/Full -This parameter i Indicates the port is configured for
10Mbps operation in full-duplex mode.
1000/Half -This parameter i Indicates the port is configured for
1000Mbps operation in half-duplex mode.
100/Half -This parameter i Indicates the port is configured for
100Mbps operation in half-duplex mode.
10/Half -This parameter i Indicates the port is configured for
10Mbps operation in half-duplex mode.
When selecting a Mode setting, the following points apply:
When a twisted-pair port is set to Auto-Negotiation, the end node
should also be set to Auto-Negotiation to prevent a duplex mode
mismatch. A switch port using Auto-Negotiation defaults to half-
duplex if it detects that the end node is not using Auto-Negotiation.
This can result in a mismatch if the end node is operating at a fixed
duplex mode of full-duplex. To avoid this problem when connecting
an end node with a fixed duplex mode of full-duplex to a switch
port, disable Auto-Negotiation on the port and set the port’s speed
and duplex mode manually.
The only valid setting for the SFP ports is Auto-Negotiation.
Flow Control - This parameter reflects the current flow control
setting on the port. The switch uses a special pause packet to
notify the end node to stop transmitting for a specified period of
time. The possible values are:
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allied Telesis AT-GS950-24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allied Telesis AT-GS950-24 in the language / languages: English as an attachment in your email.

The manual is 10,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Allied Telesis AT-GS950-24

Allied Telesis AT-GS950-24 Installation Guide - English - 50 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info