Chapter 25: Virtual LANs
280 Section II: Web Browser Interface
Configuring the PVID of Untagged Ports
This procedure adjusts a port’s VID value. The PVID value determines the
VLAN in which the port is an untagged member. A port is an untagged
member of the VLAN whose VID value matches its PVID. A port can be an
untagged member of only one VLAN at a time.
The ports of a new VLAN are initially designated as tagged ports. Their
PVID values retain their previous settings when they are assigned to a
new VLAN. If you want the ports to function as untagged members of a
new VLAN, you must change their PVID values to match the VID of the
VLAN, as explained in this procedure.
You can also use this procedure to change the VLAN assignment of an
untagged port. With this procedure you can move an untagged port from
one VLAN to another by changing its PVID value.
To adjust the PVID value of a port, perform the following procedure:
1. From the Advanced Config menu, select VLAN Config. > VLAN Port
Config.
The VLAN Port Configuration page opens, as shown in Figure 83.
Figure 83. PVID Page
2. Click the PVID field of the port whose value you want to change and
enter the new PVID value for the port. The PVID must be equal to the
VID of the VLAN where you want the port to be an untagged member.
For example, to make Port 10 an untagged member of a VLAN that
has a VID of 12, you would change its PVID to 12.
280


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allied Telesis AT-8000-8POE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allied Telesis AT-8000-8POE in the language / languages: English as an attachment in your email.

The manual is 5,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info