iDR-8 User Guide 35
Important Note: The iDR-switch provides contact closure switch inputs and open-
collector logic outputs. How these are wired to external equipment is the responsibility of the installer.
Specification details are provided here for the iDR-switch inputs and outputs. It is important that the
installer is suitably qualified and familiar with external control circuits to be able to work within the
capabilities of the unit. Allen & Heath do not assume responsibility for any damage done to the unit
due to incorrect or faulty connection to external equipment.
Connectors and grounding Pluggable Phoenix
type screw terminal connectors are used for connecting the
external switches and logic to the iDR-switch. Mating plugs
are provided with the unit. Make sure the wire ends are
carefully stripped and inserted into the terminals. Tighten the
screws using the correct slotted screwdriver. To ensure
interference-free operation use shielded cable. Connect the
shields to the chassis ground screw terminals provided next to
each connector. Fit the screws with the shake proof washers
provided.
For operator safety make sure that wall plates and
other control surfaces made from metal are correctly
bonded to ground (earth).
Strap the metal plate to the local ground at the wall box. For
ground isolation between the wall plate and equipment rack
connect the cable shield at the iDR-switch end only.
If a local ground is not available then use the cable shield to
connect the plate to the chassis of the iDR-switch unit as
shown. This is not necessary if the wall plate is made of non-
conductive material such as plastic which insulates it from the
operator.
Using the switch closure inputs The input is
opto-coupled to isolate the iDR-switch from the connected
equipment. It is switched by linking its connector pin to the
ground (‘G’) pin. Use a contact closure such as a momentary
press switch to do this.
The input pin is fed from the internal +10V reference supply
through a 2k2 ohm resistor. Around 5mA maximum current
flows when connected to ground. Combined switch and cable
resistance should not exceed 1k ohm for the switch to activate.
Each 10way connector provides 8 switch inputs. Either pin 1 or
pin 10 ‘G’ may be used as the common switch ground. One
cable can feed this ground to a bank of switches. Two are
shown in the diagram here. Do not use the chassis ground
screw which is for cable shielding and safety earthing only.
For reliable operation we recommend the use of heavy duty
sealed switches.
G
METAL WALLPLATE
CHASSIS EARTH
G
METAL WALLPLATE
LOCAL EARTH BOND
SWITCH
SWITCH
43215678GG
12 11 10 913141516GG
20 19 18 1721222324GG
INPUTS
2K2
+10V
OPTO
INTERNAL DR-switch CIRCUIT
(1 OF 8 SHOWN)
+10V
G 20191817 G21222324
V+-G13+-14+-15+-16
GROUND
OUT INDR-LINK
DC REFERENCE
VOLTAGE
INTERNAL POWER
9-16 1-8
9-12 5-8 1-4
+10V
2K2
CONTROL
CHAIN
OPTO-ISOLATED SWITCH INPUTS 1-24
OPTO-ISOLATED LOGIC OUTPUTS 1-16
OPEN COLLECTOR
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Allen-Heath iDR-8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Allen-Heath iDR-8 in the language / languages: English as an attachment in your email.

The manual is 6,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info