666839
22
Zoom out
Zoom in
Previous page
1/24
Next page
22
Eve model 2017 (2.0) manual | Version 1.0 | July 2017
ENGLISH
APPENDIX 2: DEFAULT CONFIGURATION
OF OPTIONAL FACTORY SETTINGS
The Eve charging station has the following smart charging
options:
1. Standard load balancing: the charging station divides

2. Active load balancing: similar, but expanded with the
ability to communicate with the smart meter (in your
charging station or indoor). The charging station takes
actual energy consumption and the maximum
capacity of your grid connection into account.
To simplify the order process for smart charge features,
-
tion. This appendix provides an overview of these settings.
If your installation deviates from the applicable standard
settings below, please use the Service Installer to optimally

Standard Load balancing
Model Max. current
per phase, per
socket
Max. current
(Station-
MaxCurrent)
904461011 16 A 25 A power supply
904461001 32 A 40 A power supply
904461002 16 A
25 A total for both
power supplies
904461012 32 A
40 A total for both
power supplies
Standard Load balancing
Installation requirements:
The Alfen charging station is equipped with an active
load balancing feature activated over P1 port
Communication cable with RJ11 plugs
Smart meter with available P1-port
– Communication with DSMR4.0 or higher
The charging station and the smart meter communicate
with each other over the P1 port using the DSMR protocol
(version 4.0 or higher). Data about the actual consumption
and charging needs is regularly exchanged. Whenever smart
meter capacity is limited, the charging station will apply
load balancing to manage the connected vehicles. This
prevents the charging station from overloading, or prevents

features provides for ‘peak shaving’, managing the power
supply during peak moments.
If the P1 port of the smart meter is already being used by
another device, a splitter can be used.
NOTICE!
Not all splitters are compatible. Using splitters with two
cables may prevent your charging cable from being able to
communicate with the smart meter.



standard load balancing. This limits the maximum
current(s) on the circuit(s) of the charging station.
Installation-MaxCurrent: This is the capacity of your grid

grid operator.
The table below show the standards settings for the
parameters mentioned:
Active
Load
Balancing
on 1-phase
connection
Active
Load
Balancing
on 3-phase
connection
Product
with max
input
current
Socket
side
Adopted
settings
32A per
phase
2x3.7kW
2x11kW
Station-
MaxCurrent
32 25
Installation-
MaxCurrent
40 35
2x32A
per phase
2x7.4kW
2x22kW
Station-
MaxCurrent
40 40
Installation-
MaxCurrent
63 63
Are these value inconsistent with yours? The technician
can use the Service Installer to modify these settings.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alfen Eve at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alfen Eve in the language / languages: English as an attachment in your email.

The manual is 6,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Alfen Eve

Alfen Eve User Manual - German - 18 pages

Alfen Eve User Manual - Dutch - 24 pages

Alfen Eve User Manual - French - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info