617339
8
Zoom out
Zoom in
Previous page
1/13
Next page
- 8 -
History Modes
- While in Normal Mode, press the HISTORY key to enter the History Mode.
- In the history mode, press SET key will trigger the history clear procedure: the word of “CLEAR” will
be flashing, hold the SET key for 2 seconds will clear all the history records.
- In the history mode, press the MIN/MAX key to select the record over the past 24hours at increments
of -3 hours, -6 hours, -9 hours, -12 hours, -15 hours, -18 hours, -21 hours, -24 hours.
Press the HISTORY key or key idle 30 second to return to Normal Mode
Alarm Modes
- While in Normal Mode press the ALARM key to enter the High Alarm Mode, Press the ALARM key
again to enter Low Alarm mode, press the ALARM key the third time to return the Normal Mode.
Remark: after the initial pressing of ALARM key, the display will be refreshed to show current high, low
alarm values. Normal alarm value will be displayed only for those already activated, all other not
activated values will be displayed with “- - -“or “- -“instead.
-In the High Alarm Mode press the SET key to select the following alarm modes:
1. Time alarm
2. Wind speed high alarm (0-50m/s)
3. Gust speed high alarm (0-50m/s)
4. Wind direction alarm
5. 1Hour rain high alarm (0-999.9mm)
6. 24 hour rain high alarm (0-999.9mm)
7. Outdoor humidity high alarm (1%-99%)
8. Outdoor temperature high alarm (-40˚C--60˚C)
9. Wind chill high alarm (-40˚C--60˚C)
10. Dew point high alarm (-40˚C--60˚C)
11. Indoor humidity high alarm (1%-99%)
12. Indoor temperature high alarm (-9.9˚C--60˚C)
-In the Low Alarm Mode press the SET key to select the following alarm modes:
1. Time alarm
2. Outdoor humidity low alarm (1%-99%)
3. Outdoor temperature low alarm (-40˚C--60˚C)
4. Wind chill low alarm (-40˚C--60˚C)
5. Dew point low alarm (-40˚C--60˚C)
6. Indoor humidity low alarm (1%-99%)
7. Indoor temperature low alarm (-9.9˚C--60˚C)
- In the alarm modes, press + key or MIN/MAX key to change or scroll the alarm value.
Hold the + key or MIN/MAX key for 2 second will increase/decrease digits in great steps. Press the
ALARM key to select the alarm on or off (if alarm is enabled, the speaker icon on the LCD will be turned
on indicating the alarm function has been enabled).
- Press the SET key to toggle through each alarm mode until it returns to the normal display mode.
-Press HISTORY key or key idle 30 second at any time, the alarm mode will return to Normal Mode
Canceling the Temperature Alarm While Sounding
a. When a set weather alarm condition has been triggered, that particular alarm will sound for 120
second and flash until the weather condition doesn’t meet the user set level. Press any key to mute the
alarm. When weather alarm condition was activated again within 3 hours, alarm will not sound but will
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alecto DKW-2012 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alecto DKW-2012 in the language / languages: English as an attachment in your email.

The manual is 1.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Alecto DKW-2012

Alecto DKW-2012 User Manual - Dutch - 12 pages

Alecto DKW-2012 User Manual - French - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info