Technical data 81.
Fitting the boiler 82.
Mounting a boiler in a cupboard 82:1
Fitting the ue terminal 92:2
LPG Installation 92:3
Fitting the room thermostat 92:4
Electrical installation 92:5
Fitting the heating system 103.
Connection to the heating system 103:1
Filling the heating system 103:2
Connection to hot water heater 114.
Installation inspection 115.
Read through these installation instructions carefully
before tting the boiler. The installation instructions
are approved in accordance with CE no. 048 AO-0007
for LPG boiler type 2928. In connection with follow-up
inspection of the boiler, national regulations must be
followed.
IMPORTANT WARNING!
No unit should be installed in any enclosed space
unless additional permanent ventilation of 100 cm
2
is
provided. No alteration or adjustment should be made
to any gas burner or gas supply by unauthorised or un-
skilled persons. In the event of a failure or breakdown,
turn off the gas supply at the cylinder and contact the
authorised dealer or supplier.
The installation must be carried out in accordance with
the relevant British Standard of Practice. (Particulary
BS5482 Parts 1, 2 and 3).
The Gas Safety Regulations issued by the Dept. of
the Environment, the Building Standards (Scotland)
(Consolidaton) Regulations issued by the Scottich
Develop ment Department.
In any communication it is essential to quote the model
and serial number shown on the data badge.
TECHNICAL DATA1.
Dimensions: Height Width Depth
Boiler dimensions: 1710 mm 132 mm 220 mm
Min. space required: 1850 mm 132 mm 400 mm
With immersion heater: 1850 mm 132 mm 450 mm
With immersion heater
and water heater: 1850 mm 132 mm 480 mm
Gas: Propane Butane
Power: 5,8 kW 6.7 kW
Gas consumption: Max 420 g/h Max 480 g/h
Gas pressure: I
3+
28-30/37 mbar, I
3B/P
30 mbar.
Weight of LPG boiler: 19 kg
Weight of immersion heater: 2.5 kg
(plus 0.5 kg for motor)
Weight of water heater 2959: 4.5 kg
Liquid volume in boiler: 2.6 l
Liquid volume in immersion heater: 1.0 l
FITTING THE BOILER2.
Mark out where the boiler is to stand. If the boiler is
to be positioned against a wall or bulkhead made of a
inammable material, a 1 mm air gap must be allowed.
Make holes in the oor, one for the ventilation duct and
one for the drainage hose (see g 1). The ventilation
duct can be placed either on the right-hand side or the
left-hand side, depending on space available. Cover
the hole for the ventilation duct with ne mesh netting.
Fit the chimney according to chapter 2:2.
Put a strip of realant round where the boiler is to stand.
Position the boiler and screw it in place on the oor
and wall at A g 2.
Remove the square panel on the side boiler where the
ventilation duct is to be tted by pressing the panel out
from inside the boiler casing and cutting the insula-
tion around the aperture with a sharp knife. Uncoil the
overow hose and pass down through the duct and out
through the hole in the oor. Screw the duct to the oor
and the side of the boiler.
If the boiler is tted in a cupboard a partition should be
installed to prevent inammable materials from con-
tacting hot parts of the casing etc. When immersion
or water heaters are tted cut holes in the partition, as
g. 4 for access to the water heater air cock and the
overheat reset button for overheating protection on the
immersion heater.
Fig 1
Hole for ventilation ductA.
Drainage hoseB.
Fig 2
Hole for attaching boilerA.
Fresh airB.
Protection for the exhaust pipeC.
Upper front plateD.
Lower front plateE.
Preheated fresh airF.
Carrying handleG.
Intake hoseH.
Hose clipI.
Drainage hoseJ.
Fig 3
Hole for air screw on water heater type 2959.A.
Hole for drain cock on water heater type 2959.B.
Hole for reset button for overheating protection on C.
immersion heater.
Mounting a boiler in a cupboard2:1
Mark out where the boiler is to stand. An air-space of
1 mm must be left if the boiler is to be placed next to a
wall or anything else that consists of ammable mate-
rial. A door or service hatch should be placed in front of
the boiler so that the control panel and the expansion
tank are easily accessible. The minimum distance in
front of the boiler to any ammable material should be
5 mm. Ventilation areas for the space which the boiler
is to occupy should be at least 10 cm2 at the oor
and the roof. Make holes in the oor, one for the input
8
8


Need help? Post your question in this forum.

Forumrules
1

Forum

alde-comfort-2928

Reset search

  • Where can I get an Alde control house and lid in EUROPE for a 2923/2928? Submitted on 29-8-2021 at 17:16

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alde Comfort 2928 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alde Comfort 2928 in the language / languages: English, German, Swedish as an attachment in your email.

The manual is 1,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Alde Comfort 2928

Alde Comfort 2928 User Manual - English, German, Dutch, French, Swedish, Finnish - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info