785819
24
Zoom out
Zoom in
Previous page
1/32
Next page
20
10.2 Safety and hazard warnings attached to the scalacombi
The labels attached to the scalacombi indicate the following:
Operate the scalacombi only, if the adjustment knob of the handlebar [16] is screwed
into the standpipe [15] and the adjustment knob [13] is screwed into the drive unit [6].
These knobs must be tightened to ensure that the handlebar [18] is firmly attached to
the drive of the scalacombi.
Before operating the stair climber on your own, carefully read all instructions in this
manual.
The scalacombi must only be operated by persons who have participated in the instruc-
tion session provided by the specialist dealer or an agent of Alber GmbH.
During the instruction session provided by your specialist dealer or an agent of Alber
GmbH, ensure that you are properly informed of all the functions of the scalacombi and
its operation as a stair climber. In addition, test the device by climbing a staircase with-
out a passenger to familiarise yourself with its operating behaviour.
Do not use armrests to lift the device, especially if the person to be conveyed is sitting
in the scalacombi. To ensure user-friendliness, the armrests are rotatable and detachable
(e.g. for transfer to the seat of the scalacombi) and might be inadvertently pulled off,
depending on direction of force.
11. Care and cleaning instructions, maintenance, reuse and disposal
Before carrying out any cleaning or maintenance work, disconnect the spiral cable of the handlebar from the drive unit. To do this, hold
the release sleeve of the adapter [12] and pull the adapter from the socket [11] on the control unit (see also chapter 7.1).
11.1 Care and cleaning instructions
The drive wheels [5] and the internal gear system of the brakes [4] of your scalacombi must be regularly cleaned with spirit to ensure opti-
mum brake effect. If the scalacombi is used on a daily basis, you should clean these parts once every week. If the stair climber is used less
frequently, monthly cleaning might be sufficient. During the safety inspection, which must be carried out at least every 2 years, the drive
wheels and the brakes are tested and worn parts are replaced, if necessary. All other components can be cleaned with a mild conventional
household detergent.
Clean the scalacombi only with a moist cloth.
Ensure that liquid or moisture do not penetrate the stair climber.
11.2 Maintenance
In Germany, the maintenance of medical products is regulated by law in the Medical Device Directive (MPBetreibV), Section 7. According to
this law, maintenance measures, especially inspections and servicing, are required in order to ensure continuous safe and proper operation
of medical products.
Based on our market observations, an interval of two years has proven reasonable for maintenance of our products when used under normal
operating conditions.
This guideline value of two years may vary depending on the actual use of the product and the behaviour of the user. Checking the degree
of use and the user behaviour is the responsibility of the operator.
In any case, we strongly recommend that you clarify beforehand to what extent the cost of the maintenance work for our products is cov-
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Alber Scalacombi eco S34 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Alber Scalacombi eco S34 in the language / languages: English as an attachment in your email.

The manual is 2.24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Alber Scalacombi eco S34

Alber Scalacombi eco S34 User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info