Instructions for use
14 JET 4000 / JET 5000 / JET 6000
Inox stainless steel
Units marked with the designation "INOX" are
supplied in stainless steel. The structure and func-
tion are unaffected by this.
Designated use
The garden pump is intended for private use in
house and garden. It must only be used in the
framework of the deployment limitations in accor-
dance with the technical data.
The garden pump is suitable for:
Watering and irrigating
Re-pumping and pumping out of vessels (e.g.
swimming pools)
Water extraction from streams, rainwater
butts and cisterns.
The garden pump is is suited exclusively for the
conveying of the following fluids:
Clear water, rainwater
water containing chlorine (e.g. swimming
pools)
Any other use shall be regarded as misuse.
Possible misuse
The garden pump must not be used continuously.
They are not suitable for conveying:
Drinking water
Salt water
Waste water
Foodstuffs
aggressive media, chemicals
corrosive, flammable, explosive or fuming
fluids
Fluids that are hotter than 35 °C
water containing sand and abrasive fluids.
SAFETY INSTRUCTIONS
CAUTION!
Danger of injury!
Only use the machine and the extension
cable if it is in perfect technical condition!
Damaged units must not be used.
Safety and protective devices must not
be deactivated!
Children, or people who are not familiar with
the operating instructions, are not allowed to
use the machine.
Never lift, transport or suspend the unit using
the connection cable.
Unilateral modifications or conversions of the
unit are prohibited.
Electrical safety
CAUTION!
Danger when touching voltage con-
ducting parts!
Disconnect the plug from the mains if the
extension cable is damaged or severed!
We recommend connecting a RCD (re-
sidual current operated device) having a
nominal residual current of < 30 mA.
The house mains voltage must agree with the
details quoted in the technical data, do not
use any other supply voltage.
The unit must only be operated with an
electrical installation in accordance with DIN/
VDE 0100, Part 737, 738 and 702 (swimming
pools). Protection must be provided by a 10 A
line protection switch and a RCCD (residual
current operated device) having a nominal re-
sidual current of 10/30 mA.
Use only extension cables that are suitable
for use outdoors - minimum cross-section 1.5
mm
2
. Cable drums should always be unrolled
completely.
Damaged or brittle extension cables must not
be used.
Check the condition of your extension
cable each time you start to use the
equipment.
ASSEMBLY
Setting up the equipment
1. Prepare a flat and solid location.
2. Erect the unit horizontally and safe from the
risk of flooding.
The unit must be protected from the rain
and direct water jets.
Mounting the pressure line
1. Screw the connecting nipple (Fig. B -15) with
the round seal ring (Fig. B -16) into the pump
outlet (Fig. A -3).
2. Screw the elbow nipple (Fig. B -13) with seal
ring (Fig. B -14) onto the connecting nipple
(Fig. B -15) and turn the elbow nipple in the
desired direction.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Al-ko JET 4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Al-ko JET 4000 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish, Finnish as an attachment in your email.

The manual is 4,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info