601646
16
Zoom out
Zoom in
Previous page
1/188
Next page
en
Startup
16 HWA 4000 / 4500 FCS
1. Open the filling screw (Fig. A -3) with the filter
key (Fig. C -19/A).
2. Fill with water via the filling screw until the
pump housing (Fig. A -2) is full.
3. Screw the filling screw in.
Switching the pump on
1. Open one of the closing off devices (e.g. water
cock) in the pressure line.
2. Insert the mains plug on the connection cable
into the plug socket.
The pumps starts to feed.
3. When no more air comes out with the water,
close the closing off device in the pressure
line.
The pump switches off automatically af-
ter the switch-off pressure has been re-
ached. The house water system is ready
for operation.
The LED displays are off.
If water is being fed, just the LED display
PUMP ON lights up.
Initial commissioning
In the initial commissioning, the LED displays
PUMP ON and the LED display FLOW CONTROL
flashes.
ADVICE
If no water is being drawn up via the suc-
tion line after approx. 90 seconds, the dry
running protection system switches the
pump off and the LED display ALARM
lights up. Check for leaks in the suction
line, the filter glass and all screwed fit-
tings, push the RESET button and re-
peat the initial commissioning process.
Switch the pump off
1. Remove the mains plug from the socket
2. Close one of the closing off devices (valve,
spray nozzle, water cock) in the pressure line
(Fig. B -10).
ADVICE
If no suction takes place within a period
of 180 seconds, the garden pump au-
tomatically goes to "fault" condition and
switches off.
CAUTION!
Danger of injury from hot water
In extended use against the closed pres-
sure side (>10 min.), the water in the
pump can be severely heated up and can
be emitted in an uncontrolled manner!
Isolate the unit from the mains and allow
the pump and water to cool down. Start
the unit again only after all the faults have
been rectified!
The risk of injury from hot water can arise if:
the installation is not correct
the pressure side is closed off
there is a lack of water in the suction line, or if
the pressure switch is defective.
Procedure
1. Isolate the unit from the mains and allow the
pump and water to cool down.
2. Check the unit, the installation and water le-
vel.
3. Start the unit again only after all the faults
have been rectified!
MAINTENANCE AND CARE
Check the air pressure in the storage vessel
CAUTION!
Check the air pressure in the storage
vessel at regular intervals. It must not ex-
ceed 1.5 bar (see Section "Commissio-
ning: Checking the Air Pressure in the
Storage Vessel").
Cleaning the pump
ADVICE
After conveying swimming pool water
containing chlorine or fluids that leave a
residue, the pump must be flushed out
with clear water.
1. Isolate the unit from the mains and secure
against switching on again.
The pump stops automatically.
2. Flush the pump out with clear water.
3. Insert the mains plug into the plug socket.
4. Switch the house water system on with the
on /off switch (Fig. A -6).
The pump starts automatically.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Al-ko HW 4000 FCS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Al-ko HW 4000 FCS in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 4,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info