594625
14
Zoom out
Zoom in
Previous page
1/152
Next page
14
Translationoforiginaluserinstructions
Operator presence control
The machine is equipped with an operator presence
control which stops the machine when it is released.
Danger!
Do not deactivate the function of the operator pres-
ence control.
Rear flap
The machine is equipped with a rear flap.
Visual safety indicator (Fig. C, Fig. H)
The visual safety indicator displays when the work
shaft is secured. The work shaft is secured correctly
when the green mark is visible (5 mm).
Assembly
Assemble the machine in accordance with the illustra-
tions (Figs. A, B).
Important!
The machine is not allowed to be operated unless it
has been fully assembled.
Startup
Important!
Always perform a visual check prior to startup. Do
not operate the machine if the blade system and/or
the fastening parts are loose, damaged or worn.
Comply with working time regulations in force in
your country
Always comply with the operating instructions
supplied from the motor manufacturer
Power cable safety
Only use rubber-sheathed cables with quality
H05RN-F acc. to DIN/VDE 0282 with a conductor
cross section of 3 x 1.5 mm²
The type designation must be marked on the
power cable. The plug and coupling socket must
be made from rubber or sheathed in rubber, and
be in accordance with DIN/VDE 0620
Only use a power cable with sufficient length
The power cable, plug and coupling socket must
be protected against splash water
Renew the tank or tank lock if damaged
Repairs on the power cable, plug and coupling
socket are only allowed to be carried out by au-
thorised specialist companies. A defective power
cable (e.g. with cracks, cuts, crushed or kinked
points in the insulation) is not allowed to be used
Protect the plug connections against moisture
Danger!
Do not damage or cut the power cable.
If the power cable is damaged, immediately discon-
nect it from the mains.
Electrical requirements
230 V/50 Hz alternating current
Minimum cross section
Power cable = 1.5 mm²
Minimum fusing of mains connection = 10 A
Residual-current circuit breaker (RCCB)
Maximum tripping current = 30 mA.
Establishing the mains connection
1. Connect the coupling part of the power cable to
the plug on the safety pushbutton switch.
2. Coil the power cable into a loop and hook it into
the cable strain relief. Leave the loop long enough
for the cable strain relief to be able to slide from
one side to the other.
Danger!
Never operate the machine from mains sockets
which do not have a residual-current circuit breaker.
Setting the working depth (Fig. D)
Important!
Only set the working depth if the motor is switched
off and the blade shaft is stopped.
Set the working depth of the blade shaft at the dial
selector.
1. Tilt the scarifier backwards with the handlebar.
2. Push the twist switch down and turn it to level "2".
Positions on the dial selector:
1 - 5 = Setting the working depth (Fig. D)
With new blades, set the dial selector to posi-
tion 2 at most!
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Al-ko Combi Care 38 E Comfort inkl. Box at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Al-ko Combi Care 38 E Comfort inkl. Box in the language / languages: All languages as an attachment in your email.

The manual is 6,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email