601640
19
Zoom out
Zoom in
Previous page
1/224
Next page
Maintenance and care
467 777_a 19
Cleaning the pump
ADVICE
After conveying swimming pool water
containing chlorine or fluids that leave a
residue, the pump must be flushed out
with clear water.
1. Isolate the unit from the mains and secure
against switching on again.
The pump stops automatically.
2. Flush the pump out with clear water.
3. Insert the mains plug into the plug socket.
4. Switch the house water system on with the
on /off switch (Fig. A -6).
The pump starts automatically.
Cleaning the filter
1. Unscrew the drain screw filter chamber (Fig.
A -9) of the draining opening, drain the fil-
ter chamber and close the draining opening
again.
2. Clear filter cover (Fig. A -1) using the filter key
(Fig. C -18/D) .
3. Remove the filter (Fig. C -20) from the filter
housing (Fig. A -2) and clean under flowing
water.
4. Cleaning the filter housing and clear sight filter
cover.
5. Before fitting the filter, check the filter seal
(Fig. C -19) and the housing seal (Fig. C -23)
for damage, and replace if necessary.
6. Fit the filter, screw the filter clear sight cover in
place and tighten hand-tight with the filter key.
Cleaning the check valve
1. Removing and fitting the filter (see Section
"Cleaning the Filter").
2. Check valve (Fig. C -21) and clean under flo-
wing water.
3. Replace seal (Fig. C -22) if necessary.
4. Fit check valve.
Unscrew float body
1. Pressure line (Fig. B -11) with elbow nipple
(Fig. B -13) and connecting nipple (Fig. B -15)
.
2. Unscrew screw-in nipple (Fig. D -24) with seal
(Fig. D -25) . Note the fitting position of the
float body (Fig. D -26) . Pull out the float body
and clean it.
3. Replace the float body - note fitting position.
Remove blockages
1. Isolate the unit from the mains and secure
against switching on again.
2. Remove the suction hose from pump inlet.
3. Connect the pressure hose to the water sup-
ply.
4. Allow water to run through the pump housing
until the blockage is removed.
5. Check that the pump is running freely by swit-
ching it on briefly.
6. Start the house water system again as descri-
bed.
STORAGE
ADVICE
If there is a risk of frost, the entire sys-
tem must be drained (pump, lines, stor-
age vessel and filter chamber).
1. Drain the suction line (Fig. B -17) and the
pressure line (Fig. B -11).
2. Unscrew the drain screw on the filter chamber
(Fig. A -9) and allow the water to flow out of
the pump.
The water in the storage vessel (Fig. A
-6) is pushed out by the air bellows at the
same time.
3. Screw the drain screws (Fig. A -8, 9) back in
position and store the pump, lines and storage
vessel in a frost-free environment.
DISPLAY INDICATIONS
On initial commissioning, all information appears on the display in English.
All functions can be called up using the MODE button. The standards called up are confirmed with
the SET button.
ADVICE
The information in the second line of the display are partially shown as running text which pro-
vides running information continuously. If the pump is in ALARM function, e.g. the air pressure
is too low, you cannot change the language.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Al-ko 6000 FMS premium at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Al-ko 6000 FMS premium in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 5,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info