515811
43
Zoom out
Zoom in
Previous page
1/56
Next page
43
Model No:AC -S13CK_S13HK
Version 1.0
2. RELATION BETWEEN THE CONDITION OF THE AIR CONDITIONER AND
PRESSURE AND ELECTRIC CURRENT IN COOLING OPERATION
l Carry out the measurements of pressure, electric current and temperature fifteen
minutes after an operation is started.
Condition of the air conditioner Lower pressure High pressure
Electric current during
operation
Insufficient refrigerant
(gas leakage)
Decreased Decreased Decreased
Clogged capillary tube or
strainer
Decreased Decreased Decreased
Short circuit in the indoor unit Decreased Decreased Decreased
Heat radiation deficiency of the
outdoor unit
Increased Increased Increased
Inefficient compression Increased Decreased Decreased
3. DIAGNOSIS METHODS OF A MALFUNCTION OF A COMPRESSOR
Nature of fault Symptom
Inefficient compressing of
a compressor
F Electric current during operation becomes approximately
20% lower than the normal value.
F The discharge tube of the compressor becomes abnormally
hot (normally 70 to 90)
F The difference between high pressure and low pressure
becomes almost zero.
Locked compressor F Electric current reaches a high level abnormally, and the
value exceeds the limit of an ammeter . In some cases, a
breaker turns OFF.
F The compressor has a humming sound.
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Akira AC-S13 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Akira AC-S13 in the language / languages: English as an attachment in your email.

The manual is 6,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info