PROGRAM CHANGE MODE
A Program Change, often referred to as a Patch Change, is a MIDI message used for sending data to
devices to cause them to change to a new program. This allows you to tell a hardware or software device
which sound to play. For example, if your MPK49 is controlling a piano patch on your DAW or an external
device, using a Program Change command allows you to easily switch to a synth patch.
There are two different types of Program Change messages on the MPK49:
PROG CHANGE – This event will transmit a regular Program Change message (0-127) to your DAW or an
external device, allowing you to switch between 128 different program banks.
PROG+BANK – This event transmits a Program Change message (0-127), along with a Bank L (Least
Significant Bit) Change message (0-127) and a Bank M (Most Significant Bit) Change message (0-126),
which allows access of up to 16384 different program banks. You can use PROG+BANK if your DAW or
external device supports LSB and MSB.
To enter Program Change mode, press the [PROGRAM CHANGE] button. Then, turn [VALUE] dial to
select either a PROG CHANGE or PROG+BANK event.
PROG CHANGE (Program Change)
PROG CHANGE allows you to transmit a regular Program Change
message.
1. Select PROG CHANGE with the [VALUE] dial.
2. Press [ENTER] to see the next page of parameters.
3. Press the [<] button to access the MIDI CH field – this is the MIDI
Channel which will be used to transmit the Program Change
message. You can change the MIDI Channel by turning the
[VALUE] dial. Then, press [>] to go to the next field.
4. In the PROG field, choose the program number with the [VALUE]
dial.
5. Press [ENTER] to send the Program Change message.
PROG+BANK (Program Change with Bank Change)
PROG+BANK allows you to send a Program Change with Bank
Change message to your DAW or external sound module.
1. Select PROG+BANK with the [VALUE] dial.
2. Press [ENTER] to see the next page of parameters.
3. Press the [<] button to access the MIDI CH field – this is the MIDI
Channel which will be used to transmit the message. You can
change the MIDI Channel by turning the [VALUE] dial. Then,
press [>] to go to the next field.
4. In the PROG field, choose the program number with the [VALUE]
dial. Press [>] to go to the next field.
5. In the BANK M field, select the MSB (Most Significant Bit) of
information. Press [>] to go to the next field.
6. In the BANK L field, select the LSB (Least Significant Bit) of
information.
7. Press [ENTER] to send the Bank and Program event.
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Akai professional MPK49 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Akai professional MPK49 in the language / languages: English as an attachment in your email.

The manual is 1,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Akai professional MPK49

Akai professional MPK49 Quick start guide - English, German, French, Italian, Spanish - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info