630577
125
Zoom out
Zoom in
Previous page
1/136
Next page
MPC2500 Operators Manual rev 1.0
115
Initialize to Factory Preset
Various Sample and Sequence settings can be saved to Com-
pact Flash when the file is saved. The global settings found
in the MPC2500 (listed below) are saved to the internal Flash
Memory and stored when the MPC2500 is turned off. You
can re-initialize the Factory Preset settings using the follow-
ing procedure.
01.
Turn the MPC2500 on while holding the [ERASE] key.
02. Release the [ERASE] key after the display shows [
MPC2500 (##MB installed)].
Now the MPC2500 is reset to the Factory Preset settings.
The following global settings are stored in the
MPC2500 :
Timing Correct (Note value, Swing%)
Click/Metronome (Count in, Rate, In play, In rec)
Step Edit Options (Auto step increment, Duration
of recorded notes)
Active track receive channel
Soft thru
Sync in
Sync out
Master level
Sustain pedal to duration
Truncate duration
Tap average
Footswitch 1
Footswitch 2
Autoload
LCD contrast
Adjustment of Pad Sensitivity
Each time you hit a pad, the MPC2500 determines how hard
you hit the pad, and converts this to a MIDI Velocity value.
This parameter is used to determine the strength/weakness
of the internal sound during playback.
If you find it difficult to achieve a comfortable velocity range
for your playing style, e.g. you can not get a velocity of 127
even you hit the Pad very hard, or vice versa, you get veloc-
ity 127 easily even you hit the Pad softly, you can adjust the
Pad Sensitivity and the velocity curve as desired.
* The Pad sensitivity and the Velocity curve can be adjusted
for each Pad separately.
01. Press the [MODE] key and then the [PAD 10]
(OTHER).
02. Press [F4] (PAD) key.
The Pad page will be displayed.
03. Select the Pad you wish to adjust the Pad Sensitivity
by hitting it.
The selected Pad Number will be displayed in the
upper left corner of the screen. The number of the
current Pad sensitivity and the current Velocity
curve will be displayed in Pad sensitivity field and
Velocity curve field. The velocity number will be
displayed in the right “Velocity” field depending
on how hard you hit the Pad. (The range of Veloc-
ity is between 1 and 127).
The bar meter will be displayed the strength of
pressing the Pad while pressing the Pad.
04 . Select the Pad Sensitivity field and Adjust the Pad
sensitivity number as you hit the Pad.
If the Pad sensitivity number is set to low number,
it’s harder to get a high velocity value even if you
hit the Pad hard. If the Pad sensitivity number is
set to high number, it may become too easy to get
high velocities even hitting the Pad softly.
You should set the Pad sensitivity number to 1
(Minimum), and increase the Pad sensitivity num-
ber while hitting the Pad until the velocity number
at the right displays 127 when you hit the Pad with
the strength you wish to use to get Velocity 127.
05. Select the Velocity curve field and adjust the Velocity
curve while hitting the Pad.
The velocity curve maps the strength of hitting the
Pad to MIDI velocity data. If the Velocity response
is not enough even with a range hard/soft Pad hits,
try switching the velocity curve from A-B-C- D.
125


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Akai MPC2500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Akai MPC2500 in the language / languages: English as an attachment in your email.

The manual is 12,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Akai MPC2500

Akai MPC2500 Quick start guide - English, German, French, Italian, Spanish - 74 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info