Working Principle
Refrigerant with low temperature and low pressure is compressed by the
compressor to high temperature and high pressure vapour, then cools in the
condenser (This is a forced air cooling process: room air passes condenser surface,
absorbs the refrigerant's heat in the condenser by heat exchange, then the room air
warms up and the warm air is exhausted through the air exhaust duct,) to become
high pressure liquid. The liquid flows through capillary tube to lower its pressure to
become low temperature low pressure liquid. After absorbing the heat of air in the
surface of evaporator (A forced air cooling process too: room air passes evaporator
surface, its heat is absorbed by refrigerant in tube, it cools down and flows into room
to lower the room temperature). The low temperature low pressure liquid is
evaporated in the evaporator. The refrigerant becomes vapour and flows back to
compressor. Then the refrigerant vapour is compressed in compressor again. Thus
the room temperature is lowered by circulating this operation.
fan motor
hot air
air flow2(air inflow from back)
condenser
compressor
upper fan
cool air
(heating)
lower fan
motor
lower fan
capillary
tube
air flow1
evaporator
-3-
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Akai aczp 112 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Akai aczp 112 in the language / languages: English as an attachment in your email.

The manual is 0,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info