OPERATING METHODS 55 OPERATING METHODS
OPERATING METHODS
■ Plug into a grounded 3-prong outlet.
■ Do not remove ground prong.
■ Failure to follow these instructions can result in
death, re, or electric shock.
WARNING
OPERATING METHODS
USAGE NOTICE
Electrical Requirements
■ Do not use an extension cord.
■ Do not use an adapter.
Electrical Shock Hazard
■ Power supply must be suitable for the rated voltage and have a special circuit for AC, and diameter of the power cord
should be large enough.
■ A time-delay fuse or time-delay circuit breaker is recommended.
■ All wiring must comply with local and national electrical codes and should be installed by a qualied electrician. If you
have any questions, contact a qualied electrician.
■ The wiring operation must be performed by the professional personnel by following national regulations. There must
be an electric leakage protection switch and magnetic and heat drop-off air switch with enough capacity in a xed
circuit. Do not connect earth wire to water pipe or gas pipe. When the air conditioner is not used, please pull out the
power plug or cut off power supply.
Names and Functions Remote Controller
ON/OFF key
"
"" "
MODE key
COOL mode
DRY mode
FAN mode
LED screen
key
Control panel and the function
1. "ON/OFF" key
Press once to start and press once again to stop the unit.
2. "MODE" key
Press this button to change the operation mode in order of:
COOLDRYFANCOOL
3. """►" key
In "COOL" mode press "◄" once, the SET TEMP. will decrease. Press " ►" once, the SET TEMP. will increase by
1
o
C (1
o
F). The SET TEMP. can be selected from 16
o
C (61
o
F) to 30
o
C (86
o
F).
COOL mode 1) To select a location near the door and window, install the heat emission duct.
2) Press "MODE" key to select "COOL" mode.
3) Press "◄" or " ►" key to set the suitable temp16°C(61 °F)~30°C(86°F).
CAUTION When the unit is running in the COOL mode, in order to maintain a good cooling effect, please pay
more attention to:
1) If there is direct sunlight near the window, please use the curtain to shield it.
2) Do not use other heat sources in the air conditioned room.
DRY mode Please close the door and window, in order to obtain a better dehumidifying effect:
Press the "MODE" key, select "DRY" mode, the unit will run in "DRY" mode. At this time, the upper
motor runs at the low speed and its speed is not adjustable.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Airwell AWPO-AELIAN012-C11 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Airwell AWPO-AELIAN012-C11 in the language / languages: English as an attachment in your email.

The manual is 1,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Airwell AWPO-AELIAN012-C11

Airwell AWPO-AELIAN012-C11 User Manual - German - 9 pages

Airwell AWPO-AELIAN012-C11 User Manual - French - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info