TANDEM compressors operate in automatic mode however, the operation depends on
the setting selected according to your requirements.
The air circuit follows the diagrams: compressor, heat exchanger with condensate
separator and automatic drain, absorption drier, tank and filter.
The two drier "chambers" work one at a time (Fig. 8):
compressed air trom the tank comes to chamber (1) and it is forced through several
alumina layers which absorb the humidity in the air. Therefore, when coming out the
air is "dry". A small amount of air is not used by sent to chamber (2) where it absorbs
humidity, thus regenerating the alumina layers. The small amount of air used comes
off from the solenoid valve at the base of the drier. An air blow of some minutes
means that the compressor is working properly.
6.3 First start-up
Make sure the switch is in position "0".
Plug in the compressor (single-phase model) or power the unit by the wall-mounted
main switch (three-phase model).
Single models
Start up the compressor by turning the pressure switch / remote pressure switch to
position (1) (fig.5).
Tandem modeIs
Turn the switch to position (1) (fig.7).
Press the START button to start the compressor, the led ON will light up (steady light
= the selected operation cycle is activated, flashing light = system under pressure).
The pressure switch activates the AIR signal which shows the status ot the system.
When the ESS led lights up, the drier starts operating.
When starting your compressor for the first time, make the compressor run for
about ten minutes with the air cocks open. Then close the cocks and make sure that
the compressor is running until the max. pressure allowed and shown on the EG plate
appears on the pressure gauge.
In order to stop the compressor, turn the switch fitted on the machine.
7. MAINTENANCE AND DISPOSAL
In order to keep your compressor in good working conditions we recommend you
to perform periodical servicing operations. Before performing any maintenance
operation, switch off the compressor and make all air in the tank release.
For the soundproof models, it is necessary to remove the upper case to access
the compressor unit. Use a 6-mm Allen spanner to unscrew the four screws which
fasten the case.
When removing compressor case, make sure "do not tear" the supply cable of
the cooling fan.
After the first 50 working hours, check all screw tightening, and especially head
and base screws (Fig. 9).
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Airpress 36821 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Airpress 36821 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info