594023
35
Zoom out
Zoom in
Previous page
1/56
Next page
33
6.3 TECHNICAL DETAILS
Model BM 50-400 DM 50-330
Motor (HP) 5,5 5
Fuel petrol diesel
Air tank (ltr) 50 50
Number of cylinders 3 2
Number of stages 1 1
Working pressure (bar/psi) 8 8
Max. pressure (bar/psi) 10 10
Suction capacity (ltr/min.) 400 330
Weight (kg) 70 70
7.0 MAINTENANCE
Before carrying out any maintenance jobs it is obligatory to stop the
machine and disconnect it from the power mains by pulling out the plug.
1 After the first 50 operating hours and then every 250 operating hours the oil
should be refreshed. Therefore, turn out the oil refill cap (7). Then turn out the
oil drain plug (13) and collect the old oil. If no oil runs out, turn in the oil drain
plug (13) and fill with fresh oil through the oil refill cap (7).
The right oil level is between the top of the oil level glass (12) and the red dot
on the glass.
Always respect the regulations in force for disposing of old oil and other
polluting materials!
2 Regularly drain condensation water. The drain tap is situated at the bottom of
the tank. Draining with pressure in the tank is the easiest way.
Condensate must be disposed of in conformity with the local regulations
in force (not in the sewer!).
As an alternative you can place an oil/water separator.
3 The oil level should also be checked regularly. The oil level must be between
the top of the oil glass and the red dot on it. If necessary refill with AIRPRESS
compressor oil (11).
Checking daily can prevent a lot of troubles!
Use oil of the same type as that already in the machine; do not mix
different types of oil!
4 The air filter element should be cleaned or changed regularly. This change
depends on the amount of fouling and should be done more often in dusty
situations and less often in a clean situation. For cleaning the filter element,
take out the filter container with the filter. Then clean the filter by blowing off the
dust.
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Airpress 36522 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Airpress 36522 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info