626825
11
Zoom out
Zoom in
Previous page
1/12
Next page
Instruction Manual
Instruction Manual
Airfree babyair/E40/E60/E80/E125/P40/P60/P80/P125/P150/
Airfree babyair/E40/E60/E80/E125/P40/P60/P80/P125/P150/
P800520.3.2
2
Copyright 2013 Airfree Produtos Electronicos Lda. All Rights Reserved
All rights reserved. No part of this publication may be reproduced, photocopied, transmitted, transcribed,
stored in a retrieval system, or translated into any language in any form or by any means without the
express prior written consent of Airfree Produtos Electronicos Lda.
Congratulations for having purchased your Airfree.
Airfree air puriers are manufactured under license of US Patent 5,874,050, and many other patents
pending worldwide. Airfree was designed with most advanced American and German technologies, to
drastically destroy indoor airborne microorganisms and reduce ozone.
Different from other air purier manufacturers, Airfree does not spend much time in describing fancy
technologies with difcult words and theories. Airfree offers independent efciency tests instead.
For every Airfree claim there is one independent test to prove it!
Please carefully read this manual to achieve the best air purifying results.
Enjoy your Airfree.
Thank you,
AIRFREE PRODUCTS
Index
Contents
Safety Instructions ......................................................................................................................................... 3
The Invisible Enemies ...................................................................................................................................4
Applications ...................................................................................................................................................4
Airfree and Mould ..........................................................................................................................................6
Airfree Description ......................................................................................................................................... 6
Installing and Connecting ..............................................................................................................................7
How does Airfree Work? Maintenance ..........................................................................................................8
Technical Characteristics ............................................................................................................................... 8
Airfree Independent and Efciency Tests ......................................................................................................9
Frequently Asked Questions..........................................................................................................................10
Warranty ........................................................................................................................................................12
3
Safety Instructions
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
Before plugging in Airfree slightly shake it to check for any loose parts in its interior caused by
unusual transportation event. If loose parts are noticed, please return the unit to the retailer.
Do not place your Airfree in direct contact with water and liquids which may pose electric shock
hazard and damage to the unit itself.
Do not obstruct Airfree air outlets with items such as towels, clothing, curtains, as they can
cause overheating and irreparable damage to the unit.
Airfree as any other electric equipment shall not be manipulated by children.
Always keep Airfree in its vertical position as shown in the picture. The anti-stress light will
start blinking if Airfree not in its vertical call, or if poor installed or with eventual malfunction-
ing.
Airfree shall not be placed near ammable and toxic products
.
In the event of a return for repair, make sure Airfree is well protected preferably inside its
original box to avoid further damage. Airfree nearest dealer may be seen at www.airfree.com
Do not attempt to open Airfree or touch its internal components and/ or do not insert any
objects as it may pose electric shock.
Any attempt to open or tamper Airfree will void this warranty.
To clean Airfree, unplug it from the electric outlet and use a dry cloth to wipe off its surface.
Do not attempt to open Airfree to clean it inside. Only Airfree authorized dealers have the
expertise and authorization to repair your Airfree.
If the supply cord is damaged, it must be replaced by the manufacturer, its ser-
vice agent or similarly qualied persons in order to avoid a hazard.
4
The Invisible Enemies
Most people spend around 90% of their time time indoors, at home or in the ofce.
The EPA – Environmental Protection Agency claims the quality of air indoors can be 100 times worse than
outdoors. Some factors contribute to indoor contamination:
- High concentration of people in rooms increase fungus, bacteria and virus development, and cross con-
tamination
- New building insulation techniques reduce outside air interchanges and consequently air conditioning run-
ning cost, but in turn drastically increase mould, and bacteria colonies
- Decient air conditioning duct cleaning
- Concentration of organic material such as books, carpeting, curtains, and sofas.
Good air quality indoors is a must for those affected by respiratory diseases and allergies. Contaminated
indoor air (fungus, airborne allergens, pollens, ozone) can trigger
- Asthma, bronchitis, rhinitis, and sinusitis
- Fungal infections in immune depressed patients
- Eye, throat and nose irritation
- Headaches, lethargy, irritability
- Cough and difculty in concentration
Relation between microorganisms and related diseases.
Inocolums(*) X Virulency (**)
_________________________
human Resistance
(*) Quantity of microorganisms (**) Microorganism aggressiveness
The higher “Inocolums” and “Virulency” and or the lower “Human resistance” results in greater contamina-
tion risk to people. The main contamination causes are several types of fungus, (some of them already
resistant to the most powerful chemicals and poisons), bacteria, viruses, the ne dust mite excrements and
skeletons containing powerful allergens and hazardous fungus, and the seasonal pollens.
Airfree can safely and silently destroy those allergens
Applications
Healthy rooms with pure clean air - The efcient and noiseless Airfree technology safely de-
stroys mould spores, bacteria, viruses and other airborne organic microorganisms.
Respiratory allergies and Asthma - Airfree drastically reduces airborne organic allergens and
ozone, providing cleaner and safer environment for allergic people. Airfree destroys mould spores,
bacteria, viruses, dust mite allergens, pet dander and reduces ozone, all kept to minimum levels.
Children and Newborns - Studies demonstrate that reducing dust mite allergen exposure to
young children will lessen the development of asthma.
Mould and Mildew - Airborne Mould spores that oat throughout the house potentially cause
allergic reactions. Those spores also start new mould colonies and expand existing ones. Airfree
destroys airborne mould and mildew spores, helping to prevent new contaminations.
Odours - Airfree can reduce some odours like “mildew smell” and other organic odours.
Kitchens and Pantries - The reduction of airborne fungi and spores in areas protected by Airfree
helps prevent mildew on food.
5
Video, lms, slides, sound and optical equipment - The reduction of airborne spores in rooms
protected by Airfree provides the best environment to store cameras, videos, pictures, slides,
negatives and any device potentially affected by fungi. Quietly and safely Airfree protects your
belongings and memories.
Yatches, Cruisers - Airfree safely eliminates fungi spores, mould, mildew, dust mites, bacteria,
and strange odours. Many of which contribute to many common problems to boat owners.
Ofces, Public Buildings - Populated rooms, corridors, and elevators offer a constant contami-
nation risk to employees and guests. This situation is aggravated by the ow of hazardous fungi
and other microbes entering through the A/C system, and the ozone generated by computers and
photocopiers. The spread of airborne transmittable diseases can accelerate in this environment.
Airfree is a powerful weapon in the reduction of airborne contamination by viruses, bacteria, fungi,
and a myriad of allergens.
Libraries and Museums - The fungi spores that become mould or mildew are always present.
When the temperature and moisture in the environment are suitable for germination, the spore
bursts and growth begins. This growth contaminates books, clothing, documents, and works of art.
Airfree destroys mould and mildew, providing a healthier environment for users and employees.
Pollens - Pollens are no exception and like other microorganims are totally destroyed when pass-
ing through Airfree patented sterilising core. After being destroyed the resulting harmless particles
are released back to the environment.
Ozone (O3) - Ozone is a very toxic gas that according to EPA can damage lung tissue, cause chest
pain, throat irritation and trigger asthma. The FDA, the US Food and Drug Administration, recom-
mends not to use any equipment directly or indirectly generating ozone in Hospitals or where the
patients are present. Airfree is proven to reduce ozone levels in 26%, every time air passes through
its ceramic core.
Schools, Kindergartens - Airborne transmittable diseases are a great concern for students, par-
ents, teachers, and principals. Inuenza, meningitis, rubeolla, and other nasty microbes ow freely
in the air. The use of Airfree in classrooms demonstrates the principal’s concern for their students
and staff well being. It also reduce school exposure to lawsuits, like with mould-affected diseases
so may common throughout the USA.
Viruses, Bacteria, Fungus and Germs - Airfree destroys all airborne microscopic threatening mi-
croorganisms cited above including the smallest microbes like those of meningitis, pneumonia and
scarlet fever, that can not be trapped in air lters or in other equipment using different technologies.
Scientists conrm that virus, fungus, and bacteria molecular structure (composed by proteins), can
not survive high temperatures as those seen inside Airfree patented ceramic core.
Hospitals, Clinics and Laboratories - Airborne contamination is quite a concern for most hos-
pitals. With Airfree, the hospital environment becomes safer. Airfree is indispensable in waiting
rooms, inrmaries, and recovery rooms due to its efciency in destroying airborne viruses bacteria,
and fungi. Airfree also reduces ozone that can affect patients with respiratory ailments. Laborato-
ries no longer need to stop all activities for chemical air desinfection, gaining working hours.
Restaurants - Airfree offers continuous air sterilisation. Silently, Airfree provides the
additional protection that patrons expect. All viruses and bacteria that pass through Airfree’s pat-
ented sterilising ceramic core are destroyed. Restaurants are recommended to submit their oor
plans to insure proper coverage inside their facilities.
Dust Mites - Many allergic reactions are caused by dust mites. The ne dust generated from
their skeletons and excrements contain hazardous fungus and allergens that when inhaled cause
allergic reactions. Those allergens and fungus are totally destroyed inside Airfree ceramic core.
Fungus reduction by Airfree in the indoor environment also reduces dust mite population as they
need certain types of fungus to survive.
Hotels and Retire Homes - The use of Airfree in guest rooms shows concern on behalf of the hotel
to its guests well being. The use of Airfree can contribute to a higher occupancy rate and may pro-
vide a good line of defense in case of lawsuits. Airfree has independent tests proving its efciency.
6
Guide for Airfree installation in mould contaminated rooms
1 - Install your Airfree unit in accordance with the user manual
2 - Allow your unit to run for at least one week to achieve signicant airborne mould spore reduction.
3 - Clean mould infected items and surfaces, since they are a continuous source of new spores.
It is important to stress that Airfree will not destroy or remove mould from an infected item or surface. Those
surfaces must be cleaned manually.
Airfree will prevent spores released by existing mould colonies from contaminating other areas, and will
inhibit the growth of existing and new colonies.
1- Top Lid with Air outlets
and Anti-Stress Light
2- Side Shells
3- On/Off Led
4- Base
5- Air Inlets
6- Power Cord
7- Anti-Stress Light
Dimmer
The Airfree’s anti-stress light has a esthetic effect and may be relaxing. It is possible to adjust the light
intensity using the dimmer at Airfree’s base. The light does not intervene or has any relation with Airfree’s
patented sterilisation core functioning. (*) Anti-stress lights not available in the Airfree E40/E60/E80/
E125.
2
6
7
1
3
4
5
Airfree Description
Airfree and Mould
llustration images based on Airfree Independent Test results. Results may vary depending on the room and
environment conditions.
Without Airfree With Airfree
7
Plug power cord to the nearest outlet.
Make sure the surface is dry (never place Airfree on wet oor or immerge in water) Make sure
side blue led is on. Switch on dimmer and the anti-stress light should glow from the top lid (1).
After 10 minutes the top lid should be warm.
Place Airfree on the oor. Do not install it under furniture or shelves, behind curtains as it will
reduce air ow and Airfree efciency in reducing microorganisms.
Place each Airfree® in rooms up to 16m² for E40/P40 or 24m² for E60/P60 or 32m² for E80/
P80 or 50m² for E125/P125 or 60m² for P150 or 22m² for babyair. For larger rooms use
proportionally additional Airfree® units. The use of just one Airfree ® in rooms larger than
recommended will reduce Airfree® efciency.
Airfree must be continuously on in the same room, 24 hours a day.
Airfree can only be used in rooms with minimum air volume of 330 cu. ft. (10 m3), free of
obstacles.
Airfree can be installed in rooms equipped with air conditioning and heating systems. However
it is recommended not to place Airfree nearby them to avoid potential interference in Airfree
air ow.
Do not place Airfree in the corridor to try to reach the whole house. In this case Airfree will only
reduce air pollution in the corridor area.
Airfree shall not be placed near doors or under windows to avoid sterilised air to exit the room.
Installing and Connecting
8
Technical Characteristics
Cooling Chamber
Cold and clean air is delivered to the
environment without signicant change
in room temperature and humidity.
TSS™Sterilising Ceramic Core
Inside the ceramic core 99.99% of
all microorganims are destroyed and
eliminated from the environment
Puried Air
Contaminated Air
Air Inlets
Contaminated air enters
Airfree by air convection
How Airfree works?
Contaminated air silently enters Airfree by air convection and is sterilised inside Airfree patented ceramic
core where all microorganisms are destroyed at high temperatures. Regardless of how hazardous a virus,
fungus or bacteria might be they can not resist the powerful heat inside the ceramic core and are destroyed.
The heat inside the ceramic core forces sterilised air out to the heat exchanger causing air convection,
which generates negative pressure underneath the ceramic core, so contaminated air is “sucked” in at
Airfree bottom air inlets in a continuous and silent thus efcient air ow.
The association of the ceramic core, special ceramic and air ow reduces at the same time toxic ozone.
How does Airfree Work? Maintenance
Model
E40/P40
Totally Silent
40W
220V - 240V
16m
2
1.09 Kg
height: 26.5cm
diameter: 21.5cm
Capacity
Electric
Consumption
Voltage
Noise
Weight
Dimensions
E60/P60
Totally Silent
45W
220V - 240V
24m
2
1.09 Kg
height: 10.4cm
diameter: 8.4cm
E80/P80
Totally Silent
48W
220V - 240V
32m
2
1.09 Kg
height: 10.4cm
diameter: 8.4cm
E125/P125
Totally Silent
50W
50m
2
1.27 Kg
height: 10.4cm
diameter: 8.4cm
P150
Totally Silent
52W
60m
2
1.48 Kg
height: 10.4cm
diameter: 8.4cm
Airfree
®
babyair
22m
2
45W
Totally Silent
1.09 Kg
height: 26.5cm
diameter: 21.5cm
220V - 240V 220V - 240V220V - 240V
9
Airfree Independent and Efciency Tests
Above and other tests can be seen at our web site www.airfree.com
* Certied by ISO 17025
AIRFREE EFFICIENCY TESTS BY INDEPENDENT LABORATORIES,
INSTITUTES AND UNIVERSITIES IN FOLLOWING COUNTRIES.
Laboratory Local
Reduction of
Microorganisms
Fungus Bacteria
Bank Branch
Clinical Laboratory
Chemical Laboratory
INETI*
Lisbon/Portugal
INETI*
Lisbon/Portugal
Univ. Nova of Lisbon
Univ. Complutense de Madrid
Madrid/Spain
Campana Laboratory/
São Paulo/Brazil
Technical Micronics Control
Huntesville/USA
SGS Natec Institute*
Hamburgo/Germany
69%
93%
74%
77%
90%
99%
93%
79%
94%
70%
62%
83%
78%
99%99%
Torre do Tombo
Portuguese National
Archive
RTP Video Archive
INETI*
Lisbon/Portugal
AINIA
Valença Spain
Cold Chamber
Laboratory
86%
Laboratory
Laboratory Ofce
Dust Mite alergens
DerP-1
70,6% to 97,95%
Insect R&D Limited
Laboratory
june 9 to august 22, 2003
may 7 to june 18, 1999
october 21, 1997
april 14 to april 29, 1999
september to november, 2000
january 13 to february 18, 1999
april 28 to may 14, 1998
june 5, 1998
april 3 to may 5, 1998
june, 2005
INETI*
Lisbon/Portugal
november 12 to december 10, 2004
Closed Environments
98%
87%
INETI*
Lisbon/Portugal
march 19 to april 30, 2001
Hotel Rooms
92% 82%
Cambridge, UK
10
1. How does Airfree work?
Airfree destroys microorganisms at its heated capillaries. Contaminated air is dragged into Airfree’s ceramic
core by air convection and microorganisms are destroyed at high temperatures regardless of how resistant
and dangerous they might be.
2. Are there any side effects?
No. Airfree’s new technology uses heat to purify the air. No side effects, no
emissions, NO IONS, nor new particles are generated. Airfree should be used in all homes and ofces, qui-
etly, constantly, and efciently purifying the air.
3. My Airfree does not stop blinking. What does that mean?
Cause 1: Airfree incorporates an automatic energy-saving feature by automatically shutting off the ceramic
core when it has reached a temperature range to facilitate air convection (air in the room is drawn into the
machine to destroy impurities, contaminants and odours). The ceramic core shuts down for a few minutes,
the indicator light turns off, and the top lights emitting diode (L.E.D.) blinks. Airfree continues to sterilise the
air during this time. This indicates the conservation of electric power consumption and the preservation of
the ceramic core.
Cause 2: Another contributory factor to Airfree’s blinking occurrence is the ambient air (air in the environ-
ment). When the ambient air reaches 35 ºC, Airfree auto-regulates itself with the ceramic core “shut off” for a
few minutes but still continues with its sterilising activity (the blinking of the top lights signals this occurrence).
In this process energy is conserved and Airfree’s safety mechanism is enhanced.
Cause 3: Airfree incorporates state of the art electronics detecting any improper placement or device mal-
functioning. If the top lights does not stop blinking, please ensure that your Airfree unit is in the upright posi-
tion. If the top and bottom air inlets are free of blockage, the blinking may be due to a faulty electrical outlet.
Please plug it in into a proper outlet. If in the next 10 minutes the top lights continues blinking and your Airfree
unit is correctly installed, this indicates that the device may be malfunctioning. Please promptly contact your
dealer in such case. (*) The Airfree® E40/E60/ E80/ E125 does not incorporate the Anti-stress lights.
4. Is there any risk when the top light of Airfree is blinking?
No. When Airfree electronics detect any irregularity it automatically shuts off the TSS™ ceramic core
(*) The Airfree® E40/E60/ E80/ E125 does not incorporate the Anti-stress lights.
5. What is Airfree’s air cleaning capacity?
E40/P40 was designed for rooms up to 16m². E60/P60 for rooms up to 24m². E80/P80 for rooms up to 32m².
E125/P125 for rooms up to 50m². P150 for rooms up to 60m². Airfree babyair for rooms up to m².
6. Can I install Airfree in my walking closet ?
Yes, as long as it has at least 330cu.ft (10m³)*. Airfree should not be placed under shelves or its efciency
will be reduced.
* as reference 330cu.ft (10m³) is approximately 7’x7’
7. Can I use Airfree in air conditioned rooms?
Yes.
8. How do I know if Airfree is no longer working?
Check the top lid, if warm Airfree is working.
9. Can I place Airfree at the corridor to reach the whole house?
No. Airfree will just reduce air pollution in the corridors area.
10. Can I place Airfree in a closed room?
Yes. Please remember such a room must have at least 330cu.ft (10m3)*.
* 330cu.ft is approximately 7’x7’
11. Does Airfree eliminate bacteria and viruses?
Yes. Unlike the air lters in the market Airfree is more efcient with the smallest microorganisms as they are
easily carried by Airfree’s airow into its heated ceramic core.
Frequently Asked Questions
11
12. Can I change Airfree from one room to another?
Airfree must always be plugged in the same room 24 hours a day. Airfree’s patented technology works
gradually and cannot have its cycle interrupted. Moving it from one room to another will interrupt the cycle
and will recontaminate the room. See question 13 bellow.
13. Should I turn off Airfree when I leave house?
No. Airfree must always be on.
14. What happens if Airfree is disconnected or there was a black out?
Airfree will take approximately the same time to recover the previous reduced contamination level.
15. Does CADR measure the effectiveness of the Airfree?
Not at all. CADR is not designed to test the Airfree technology. The AHAM seal (usually found on the back
of an air cleaner’s box) lists three Clean Air Delivery Rate (CADR) numbers: one for tobacco smoke, one for
pollen and one for dust. The CADR indicates volume of ltered air delivered by an air cleaner. The higher
the tobacco smoke, pollen and dust numbers, the faster the unit lters the air. The main reason why CADR
is not designed for Airfree is because Aifree does not lter but destroys microorganisms instead, CADR only
applies to volume of ltered air delivered by an air cleaner as stated above. CADR does not measure micro-
organism reduction like mould and bacteria only detectable by a microbiology lab. Airfree destroys (not trap
or attract to other surface) any microorganism regardless of how small they might be. 99,99% of all organic
particles are fully destroyed when passing through the Airfree U.S. patented ceramic core.
16. How does Airfree destroy dust mites?
Mould reduction in the environment causes reduction in the mould dependant dust mite population. Airfree
also destroys the harmful toxins and fungus freed by dust mite feces that trigger respiratory allergies.
17. How does Airfree eliminate fungi?
As mentioned before, Airfree eliminates airborne microorganisms included fungi and spores. By eliminating
spores new colonies are unlikely to develop, representing less future airborne spores.
18. How does Airfree destroy viruses?
Those microscopic microorganisms are easily eliminated inside Airfree’s ceramic core capillaries. The tem-
perature inside of Aifree’s capillaries is much higher than required to destroy them. Airfree is your greatest
ally in respiratory disease prevention.
19. Does Airfree reduce tobacco smell?
Yes, Airfree reduces any kind of organic smell in the ambience including tobacco.
20. Does Airfree release any gas or chemical product?
No. Airfree’s sterilisation process is natural. Please check our website for conclusive tests regarding par-
ticles and ozone.
21. Does Airfree heat up a room?
No. Airfree does not noticeable increase room temperature. To have an idea 2 Airfrees plugged in the same
room will contribute as much heat as the presence of one adult in that same room.
22. Does Airfree provoke any change in room’s the relative humidity?
No.
23. Does Airfree need lter replacement?
No.
24. Does Airfree consume a lot of energy?
No. Airfree’s consumption is just 40 Watts for E40/P40, 45 Watts for E60/P60/BabyAir, 48 Watts for E80/
P80, 50 Watts for E125/P125 and 52 Watts for P150.
Frequently Asked Questions
12
25 - Does Airfree anti-stress light interfere with Airfree sterilising function?
No. The anti-stress light has an esthetic effect may be relaxing or simply used as a night light in children or
newborn bedrooms. According to chromo therapy the blue light has calming and relaxing effect.
26 - Where do the microorganisms go after they are destroyed?
As all living organisms, microorganisms and their products are basically composed by carbon, oxigen and ni-
trogen. Since Airfree reachs nearly 200°C, all the components are supposed to suffer a combustion process,
which liberates carbone dioxide (the same product released by our respiration) and water. Some carbon (or
ashes) may remain in the process. If there is some residual allergen left, we might consider that they suffer
denaturation, a process involving lost of conformation and function.
It should be noted that we are talking about reactions that occur in a microscopic level, so all these pro-
cesses or by-products won’t be perceived. In this case, there is no need to worry about maintenance.
Frequently Asked Questions
Warranty
This product is warranted by AIRFREE® PRODUCTS, to the original purchaser to be free from defects in
material and workmanship under proper use for a period of two years from date of purchase. During this
period, and upon proof of purchase and date of purchase, this product will be repaired or replaced with same
or similar model without charges for parts or labor (except for a €10 charge for insurance and handling) at
distributor address. To be eligible for the warranty, please register at www.airfree.com or complete your war-
ranty card at the time of purchase and mail it to the distributor. To obtain warranty service, please send the
product sales receipt or proof of Purchase, and a check or money order for €10 payable to the distributor.
This warranty does not apply to a product that has been misused, abused, or altered without limiting the
afore-mentioned, bending or dropping the unit, defects in the electrical installation or uctuating power levels
are presumed to be defects resulting from misuse or abuse.
AIRFREE® PRODUCTS and its afliates or wholesalers do not make any specic claim as to medicinal
uses of this product nor does the manufacturer warrant that the equipment prevents some kind of diseases.
NEITHER THIS WARRANTY NOR ANY WARRANTY, EXPRESSED OR IMPLIED, INCLUDING IMPLIED
WARRANTIES OR MERCHANTABILITY, SHALL EXTEND BEYOND THE WARRANTY PERIOD. NO RE-
SPONSIBILITY IS ASSUMED FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING
WITHOUT LIMITATION DAMAGES, SOME STATES DO NOT ALLOW LIMITATION ON HOW LONG AN
IMPLIED WARRANTY LASTS; SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY
NOT APPLY TO YOU.
AIRFREE® PRODUCTS HEREBY SPECIFICALLY DISCLAIMS ALL EXPRESSED WARRANTIES NOT
OTHERWISE SET FORTH HEREIN AND ANY IMPLIED WARRANTIES OR MERCHANTABILITY OR IM-
PLIED WARRANTIES FOR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES
WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. This warranty gives you specic
legal rights; you may have other rights, which vary from state to state, and country to country.
* AIRFREE® PRODUCTS, Rua Mouzinho da Silveira Nº27 - 5A - 1250-166, Lisbon Portugal
- Tel.:351 - 213 156 222
- Fax: 351 - 213 516 228
- Web: www.airfree.com
- Mail: info@airfree.com
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Airfree Babyair P40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Airfree Babyair P40 in the language / languages: English as an attachment in your email.

The manual is 0,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info