506414
26
Zoom out
Zoom in
Previous page
1/54
Next page
26
Replacement of the d
e
mi
n
e
rali
s
a
t
i
o
n
car
tridge
A
lw
a
y
s
sw
i
tc
h
off the
ap
p
li
a
n
c
e
before
r
e
m
o
v
i
ng
the water tank. Do not reach
i
n
s
i
d
e
the
n
e
bu
li
s
e
r
en
space
while
the
appliance
is
running!
The
c
a
r
t
r
i
dg
e
must
be
r
e
p
l
a
c
e
d
every
2 – 3
months.
If
the
water is very hard, it may
be
necessary to replace the
cart-
r
i
dg
e ea
r
li
e
r
.
White dust around the
ap
p
li
a
n
c
e
i
s
a
sure
s
i
gn
that the
cartridge
needs
replacing.
If
white residues
con-
t
i
nu
e
s
to
form around
the
ap
p
li
a
n
c
e
after
a
new
c
a
r
t
r
i
dg
e
has
been
i
n
s
e
r
t
e
d
,
p
l
ea
s
e
make sure that the water you
are
u
s
i
ng
i
s
untreated.
If
the water
flows through
a
d
o
m
e
s
t
i
c
decalcification system before it
is used
in
the
unit, salt
will
precipitate around
the appliance.
Option A: Replace the
granules
Remove
the
water tank from
the base
and unscrew
the
water tank
cap (25).
The
d
e
m
i
n
e
r
a
li
s
at
i
o
n
c
a
r
t
r
i
dg
e
i
s
attached to
the
i
n
s
i
d
e
of
the
cap.
U
n
s
c
r
e
w
the
c
a
r
t
r
i
dg
e
from
the cap
b
y
t
u
r
n
i
ng
it
c
o
un
t
e
r
-
c
l
o
c
k
w
i
s
e
(
26
)
.
I
mp
or
t
a
n
t
:
do
NOT
dispose of
the
tank
cap!
Open
the
cartridge
(27).
Throw
the
content (granules) into
the
waste (28).
Atten-
tion! Disposed granules
can
make
the
floor
slipper
y!
P
l
a
c
e the e
n
c
l
o
s
e
d
pink styrofoam
p
i
e
c
e
in
the center
of
the
c
a
r
t
r
i
dg
e
.
Do not push it to
the
bottom
as
it
w
ill
be
difficult to remove afterwards
(29).
Pour
the
contents of one
refill
r
e
s
i
n
bag into
the
p
l
a
s
t
i
c
cup that
is
included with
the
refill resin packaging
(30).
P
l
a
c
e the
empty
c
a
r
t
r
i
dg
e
with
the
p
l
ug
in
the center
onto
the
plastic cup
(31).
Turn
the
p
l
a
s
t
i
c
cup and c
a
r
t
r
i
dg
e
over and shake un
t
il
all granules
are
in
the
cartridge
(32).
Remove
the
p
l
a
s
t
i
c
cup and
the
pink styrofoam
p
i
e
c
e
from
the
c
a
r
t
r
i
dg
e
(33) and r
e
t
a
i
n
for future
use
(
t
h
e
refill
resin consists of
3
refill bags)
(34).
Close
the cap (35).
Soak
the
d
e
m
i
n
e
r
a
li
s
at
i
o
n
c
a
r
t
r
i
dg
e
in
a
bowl of
water
for
at
l
ea
s
t
24
hours before
use
(
38
)
.
The
g
r
a
nu
l
e
s
have
to absorb water to reach full
performance.
Now screw
the
cartridge onto
the
water tank
cap (39).
Close
the
tank
cap
s
e
c
u
r
e
l
y
!
P
l
a
c
e the
water tank
onto
the base (40).
Option B: Replace the entire
car
tridge
Remove
the
water tank from
the base
and unscrew
the
water tank
cap (25).
The
d
e
m
i
n
e
r
a
li
s
at
i
o
n
c
a
r
t
r
i
dg
e
i
s
attached to
the
i
n
s
i
d
e
of
the
tank cap.
U
n
s
c
r
e
w
the
c
a
r
t
r
i
dg
e
from
the cap
b
y
t
u
r
n
i
ng
it
c
o
un
t
e
r
-
c
l
o
c
k
w
i
s
e
(
26
)
.
I
mp
or
t
a
n
t
:
do
NOT
dispose of
the
tank
cap!
Dispose of
the
old cartridge
(36).
Unpack
the
new cartridge
(37).
Soak
the
new
c
a
r
t
r
i
dg
e
in
a
bowl of water for
at
l
ea
s
t
24
hours before
use
(
38
)
.
The
g
r
a
nu
l
e
s
have to
absorb
water to reach full
performance.
Now screw
the
cartridge onto
the
water tank
cap (39).
Close
the
tank
cap
s
e
c
u
r
e
l
y
!
P
l
a
c
e the
water tank
onto
the base (40).
25
26
27 28
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Air-O-Swiss AOS U650 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Air-O-Swiss AOS U650 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Air-O-Swiss AOS U650

Air-O-Swiss AOS U650 User Manual - English, German, Dutch, Danish, French, Italian, Polish, Swedish, Spanish, Norwegian, Finnish - 78 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info