521963
40
Zoom out
Zoom in
Previous page
1/47
Next page
offered by Busse-Yachtshop.com
AIR 403 Land Manual Document #0049 REV D
SOUTHWEST WINDPOWER 8/20/2001 40
wire connections are very solid, have no gaps, have no corrosion, and no crimp
terminals are used. If your turbines are at various distances from the batteries, make
sure turbines with longer wire runs have bigger wires.
There will be some variation at what voltage turbines will enter into regulation based
on the relative wind to which each turbine is exposed. Small differences in line loss
can be significant in strong winds.
Accessories
#18 Where can I locate a stop switch?
If you want to install a stop switch it must be a 50-amp or greater DC Single-Pole
Double-Throw toggle switch (see Section 3.1.5 on page 12). This can be purchased
from some automotive electrical repair shops, your dealer, or from Southwest
Windpower direct.
#19 Can I use household AC fuses or breakers to fuse my AIR?
You should only use DC rated devices with your AIR 403, as AC components are
typically sized differently. Because DC breakers and fuses in the required sizes may
be hard to find in your area, Southwest Windpower carries a 50A and 100A breaker.
You may purchase these from some local dealers and distributors or from Southwest
Windpower direct.
#20 Can I use an external charge controller to regulate my AIR?
We recommend using only diversion load type charge regulators with the AIR 403.
These regulators divert excess power to a heating element or power resistor when
the batteries are full. This excess power can be used to assist in hot water or room
heating. PV type regulators should never be used. Series type regulators that
disconnect the power source when batteries are full will often give undesirable results
such as causing the Autobrake to fluctuate on and off when the batteries become full.
#21 I just installed my AIR with an automotive style amp meter, but I don’t see any
current. How can this be?
Given that all wiring has been done correctly, and other precautions have been
heeded, chances are that the amp meter is wired backwards and the needle is
attempting to move in the negative direction. If “zero” is on the left-hand side of the
meter, then the needle cannot move and looks as if the unit is not producing. Simply
reverse the leads on the meter and see if current will register.
#22 Where can I locate tubing to make a tower?
The AIR uses 1 1/2” schedule 40 steel pipe. (Actual outside diameter (O.D.) of the
pipe is 1.875 inches, 48 mm) Steel pipe is available at any hardware or plumbing store.
Wiring
#23 The recommended wire sizes on your chart seem small for 400 Watts output.
Why is that?
Because the output of the AIR follows the cubic power in the wind, the output
increases rapidly with increasing wind speed until flutter occurs and the output power
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Air Marine Air 403 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Air Marine Air 403 in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info