Basic aerodynamics show that as wind moves over or around objects, the wind compresses
and accelerates. It is possible to use a building rooftop to increase the turbine’s output using
this accelerated wind. The amount of acceleration will vary greatly with house design, wind
direction, local obstructions and terrain.
There are considerable differences in acceleration due to the angle and height of a structure
and nearby obstructions. However, a location of 5 feet (1.5 m) to 8 feet (2.5 m) above the
structure produces substantial acceleration in average situations and is tolerant of different
wind directions.
For ideal sites where the prevailing wind is perpendicular to the roof-ridge line, the AIR 403s
may be mounted fairly close together 9 feet (2.75 m), center to center. However, if your wind
primarily comes from a direction along the roof-ridge line, then the AIR 403s must be spaced
to minimize interference 12 to 15 feet (3.6 to 4.5 m) and mounted as high as possible (8 feet
(2.5 m) maximum unsupported pipe). Less acceleration occurs when the wind is parallel to
the roofline.
When the prevailing wind is perpendicular to the roof edge, mount your first AIR 403 in the
center of the roof ridge and add modules to either side along the roof ridge. Where the
prevailing wind parallels the roof-ridge line, mount your first AIR 403 on the end of the
structure closest to the wind, and about 3 feet (1 meter) from the edge.
Although a rooftop can be used to accelerate the wind flowing past a house, a tower that is
much taller will experience higher winds and greater output. The advantages of rooftop
mounting are ease of mounting, low tower cost and multiple installations. The disadvantages
are lower wind speeds, increased turbulence and noise.
NOTE: Uniform building code requires that a structure must support the wind load it creates
by the area presented to the wind. The structural load applied by the wind increases with
wind speed. Any additional loads that increase area during serious storms must be
compensated for.
NOTE: Any wind generator can create vibration. Always use some type of vibration isolator
when attaching the turbine to a structure. If available it is always better to mount a wind
generator on an unoccupied building.
CAUTION: DO NOT INSTALL THE TURBINE WHERE THE PATH OF THE
BLADES CAN BE REACHED DURING NORMAL OPERATION,
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Air Marine Air 403 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Air Marine Air 403 in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info