AIR 403 Land Manual Document #0049 REV D
SOUTHWEST WINDPOWER 8/20/2001 18
NOTE: Do NOT accidentally connect the turbine “backwards” to the battery for even a
second (i.e. turbine positive to battery negative and turbine negative to battery
positive). Doing this will instantly destroy the circuit inside the turbine and void your
warranty.
3.2 Mounting To Tower
The AIR 403 is designed to be mounted on tubing or pipe 1.875 inch (48mm) outside
diameter. This is equivalent to 1 ½ inch SCH 40 pipe, which can be used in some tower
applications. There is a soft coupling inside the yaw shaft mount that is designed to provide
a secure fit and to dampen some of the noise transmitted down the tower. The pole must be
mounted with hardware specifically designed for small wind turbines. Southwest Windpower
offers a complete stand-alone tower package and a “Roof Mount Kit” for mounting to
structures, which provides secure mounting and superior noise isolation. Contact your
dealer for details.
CAUTION: Only use properly sized metal pipe for towers.
3.2.1 Attaching to Pole
While attaching the turbine to the tower, be careful not to pinch the yaw wires. Slide the yaw
all the way down over the end of pole. After the yaw is seated on the pole, move it back up a
1/8th inch (2mm) to prevent the bottom of the yaw from contacting the top of the pole. This
way the only contact between the tower and yaw is through the rubber pad, which will reduce
noise transmission. Tighten all mounting fasteners to 3 - 5 foot lbs. (4.1-6.8 N.m.).
Make sure that your tower allows for proper clearance of the blades. A minimum
2-inch (20 mm) clearance must be given between the blade tips and any obstructions. Refer
to Figure 6 below, and the “Sphere of Operation” drawing in Section 7.2 on page 27 for
proper clearances.
Figure 6 Proper Blade-to-Tower Clearances
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Air Marine Air 403 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Air Marine Air 403 in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info