459306
17
Zoom out
Zoom in
Previous page
1/47
Next page
17
MegaDens 3 122 / MegaDens 4(SHR) 126 / MegaDens 5(SHR) 131
8.4 Afmetingen en aansluitingen MegaDens 4SHR 126 en 5SHR 131
Figuur 8.3 Afmetingen en aansluitingen van de
Ferroli MegaDens 4SHR 126 en 5SHR 131
Maten in mm.
5SHR 131
500
320
136
256
376
122
217
268
322
402
195
135
MegaDens type
A Toestelbreedte
B Toesteldiepte
C Linkerzijde - linker luchttoevoer
D Linkerzijde - rookgasafvoer
E Linkerzijde - rechter luchttoevoer
F Linkerzijde - cv-aanvoeraansluiting
G Linkerzijde - warm wateraansluiting
H Linkerzijde - gasaansluiting
I Linkerzijde - koud wateraansluiting
J Linkerzijde - cv-retouraansluiting
K Achterzijde - gas-/wateraansluitingen
L Achterzijde - cv-aansluitingen
4SHR 126
450
320
120
240
360
107
184
237
288
369
167
107
5SHR 131
450
370
25
3/4’’ incl. Z
1/2’’ incl. Y
1/2’’ incl. Y
1/2’’ incl. Y
ø 22
3/4’’ incl. Z
80
80
ø 15
ø 22
MegaDens type
M Ophangbeugel
N Toestelophangpunten
O Ophangpunten ophangbeugel
P Condensafvoer (slang ø buiten)
Q Aansluiting cv-aanvoer
R Aansluiting warm water
S Aansluiting gas
T Aansluiting koud water
U Overloop ontlastklep cv. (rubber, ø buiten)
V Aansluiting cv-retour
W Aansluitingen luchttoevoer
X Aansluiting rookgasafvoer
(ook concentrisch, mat adapter)
Y Aansluitpijp tapwater/gas
Z Aansluitpijp cv-aanvoer/retour
4SHR 126
400
320
25
3/4’’ incl. Z
1/2’’ incl. Y
1/2’’ incl. Y
1/2’’ incl. Y
ø 22
3/4’’ incl. Z
80
80
ø 15
ø 22
Benodigde vrije ruimte rondom het toestel
Advies: Minimaal:
Zijkant 150 mm 40 mm
Onderkant 1 meter 250 mm
Voorkant >500 mm 500 mm
(15 mm bij gesloten deur)
Bovenkant afhankelijk van 280 mm (concentrische
rookgasafvoer geveldoorvoer)
Let op!
Bij afwijking van de
geadviseerde vrije ruimte
wordt de bereik-baarheid
van het toestel voor
servicedoeleinden beperkt.
incl. ophangbeugel M
De getekende versie is de MegaDens 4SHR
Borg het toestel met
bijvoorbeeld 2 parkers
aan ophangbeugel-M.
(links en rechts)
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Agpo Ferroli MegaDens4SHR 126 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Agpo Ferroli MegaDens4SHR 126 in the language / languages: Dutch as an attachment in your email.

The manual is 2,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Agpo Ferroli MegaDens4SHR 126

Agpo Ferroli MegaDens4SHR 126 Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info