Fuels should be stored under cover, particularly
manufactured fuels which must be kept dry. Wet kitchen
refuse should not be burned and the appliance should not
be used as an incinerator.
Rayburn 200SFW and 212SFW: Provision must be
made for additional ventilation. A permanent unobstructed
air vent having a minimum effective area of 11 cm
2
must
communicate to outside air or an adjacent room which in
turn has a permanent vent of at least the same size to
outside air.
If a flue draught stabiliser is fitted in the flue this vent size
must be increased to a minimum 23.5cm
2
. If this
appliance is used with an additional appliance of a similar
type then the air supply must be adequate for both
appliances in accordance with Building Regulations.
Any air inlet grilles must be maintained so that they are
free from blockage.
OVEN DOOR OPERATION - SEE FIG. 1
To open the doors. Twist the handle slightly to lift up the
door catch from the locking spindle and pull the door
open.
To close the doors. Gently push the door shut until the
door catch makes contact with the locking spindle.
FIRE DOOR/ASHPIT DOOR OPERATION
The fire door and ash pit door are kept closed by a turn
screw. A tool is supplied to operate these when hot and
they can be adjusted to ensure both these doors close
tightly. IT IS IMPORTANT TO ENSURE PROPER
CLOSURE OF THESE DOORS TO PREVENT
OVERFIRING.
DOOR OPERATION
DESN 512979
DESN 514177
2
Fig. 1
Fig. 2