PRECAUTIONS
Notice for the LCD Display
The intended use of the MD-24, MD-27 is to serve as a LCD monitor for integration with the hospital
system.It is designed for general purpose for adults using at hospital environment,continuous operation. For
displaying and viewing of images for reference. The use of this device does not require any direct contact
with patients.
Accessory equipment connected to the analog and digital interfaces must be in compliance with the
respective nationally harmonized IEC standards (i.e. IEC 60950 for data processing equipment, IEC 60065
for video equipment, IEC 61010-1 for laboratory equipment, and IEC 60601-1 for medical equipment.)
Furthermore all congurations shall comply with the system standard IEC 60601-1-1. Everybody who
connects additional equipment to the signal input part or signal output part congures a medical system,
and is therefore, responsible that the system complies with the requirements of the system standard IEC
60601-1-1. The unit is for exclusive interconnection with IEC 60601-1 certied equipment in the patient
environment and IEC 60XXX certied equipment outside of the patient environment. If in doubt, consult the
technical services department or your local representative.
Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle
marked “Hospital Only” or “Hospital Grade”.
Use a power cord that matches the voltage of the power outlet, which has been approved and complies
with the safety standard of your particular country.
The single device output analog signals through ADC element (Analog DigitalConvert) conversion to
become a digital signal and the video signal is via Video Decorder conversion. It has become the same
digital signal, these signals via Scaler IC as zoom in or out action and digital image processing, then
through the cable line transmission LVDS signals to one of the LCD module. The last by the clock controller
(Timing Controller, TCON), the clock signal is transmitted to the drive IC on the panel and turn on Backlight
for LCD module light source by Scaler control.
WARNING: No protection against the ingress of water : IPX0
WARNING: Do not modify this equipment without authorization of the manufacturer. Installation and OSD
adjusting should only be carried by manufacturer trained and authorized personnel.
WARNING: To avoid risk of electric shock, this equipment must only be connected to a supply mains with
with protective earth.
CAUTION: This adapter Manufacturer/model is a forming part of the medical device.
♦ Power by class I power supply.
Adapter manufacturer/model:
ADAPTER TECH: ATM065-P120/ATM065T-P120
Input/output: 100-240V~50-60Hz, 12V( ) 5A.
EDAC TECH:EM10681G
Input/output: 100-240V~50-60Hz, 12V( ) 4.16A.
WARNING: Use suitable mounting apparatus to avoid risk of injury.
WARNING: The equipment not suitable for use in the presence of a ammable anesthetic mixture with air
or with oxygen or nitrous: Not AP or APG Category
CAUTION: No applied part.
Make sure the user not to contact medical device and the patient at the same time.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ag neovo MD-24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ag neovo MD-24 in the language / languages: English as an attachment in your email.

The manual is 7,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ag neovo MD-24

Ag neovo MD-24 User Manual - German - 39 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info