Índice - Línea Significado de la Lectura
Temperatura salida agua
Temperatura entrada agua
Temperatura batería
Temperatura gas impelente
Temperatura exterior
Presión de ventilación
Presión de aspiración
Termostato
Banda de seguridad sobre el force-off
Tiempos CP
Horas de funcionamiento (miles)
Horas de funcionamiento (unidad)
Arranques compresor (miles)
Índice - Línea Significado de la Lectura
Arranques compresor (unidad)
Release del software
Release menores del software
Set actualmente en uso
Set presión DCP
Diferencial de presión DCP
Horas de funcionamiento
COMPRESOR 2 (miles)
Horas de funcionamiento
COMPRESOR 2 (unidades)
Arranques del compresor
COMPRESOR 2 (miles)
Arranques del compresor
COMPRESOR 2 (unidades)
Fracción de potencia
Frecuencia requerida (INVERTER)
Caída de presión
Menú lecturas
Para ingresar al menú lecturas pulsar la
tecla en (Fig.4); una vez ingresados al
menú lecturas, en la pantalla se visua-
liza el índice de la lectura y una línea
de tres caracteres que la identifi ca; la
línea se puede visualizar un segundo,
luego se sustituye por el valor corres-
pondiente a la lectura misma. Para pa-
sar a la lectura siguiente es necesario
pulsar la tecla en (Fig.5),
mientras que
para volver a la anterior, es preciso pul-
sar la tecla en (Fig.6). Cada vez que se
pasa de una lectura a otra, además del
cambio del valor del índice, se visuali-
zará en el primer segundo la línea para
identifi car la lectura en curso (sin em-
bargo es posible identifi car cualquier
lectura mediante el valor del índice,
comparándolo con la tabla indicada
más abajo).
Lista de índices y respectivas lecturas MENÚ USUARIO (ninguna password)
Parámetro visible en TODAS las unidades
Parámetro visible SÓLO en unidades adecuadas
para la
producción de agua caliente
Parámetro visible SÓLO en unidades con dispositivo
de control de la condensación incorporado
Parámetro visible SÓLO en unidades dotadas de
bicompresor
Parámetro visible SÓLO en unidades dotadas de
compresor inverter
159


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aermec MODUCONTROL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aermec MODUCONTROL in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 3,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info