Variables digitales
R = Código mando Modbus =1
R/W = Código mando Modbus = 5
Dirección Modbus Descripción R/W
49 R
50 R
51 R
52 R
53 R
54 R
55 R
56 VSBP - Válvula bypass descongelamiento circ. 1 R
57 VSBP - Válvula bypass descongelamiento circ. 2 R
58 R
59 R
100 Suma de todas las alarmas R
101 AL38 - alarma flujóstato evaporador R
102 AL39 - alarma flujóstato recuperación R
103 AL24 - Alarma térmica bomba evaporador 1 R
104 AL25 - Alarma térmica bomba evaporador 2 R
107 AL26 - Alarma térmica bomba recuperación 1 R
108 AL27 - Alarma térmica bomba recuperación 2 R
115 AL28 - Alarma térmica ventilador 1 R
116 AL29 - Alarma térmica ventilador 2 R
117 AL40 - Alarma anti congelamiento evap. R
121 AL31 - Alarma de baja presión circ. 1 R
122 AL65 - Alarma baja presión circ. 2 R
123 AL34 - Alarma baja presión grave circ. 1 R
124 AL35 - Alarma baja presión grave circ. 2 R
125 AL32 - Alarma presostato alta circ. 1 R
126 AL66 - Alarma presostato alta circ. 2 R
127 AL33 - Alarma de alta presión circ. 1 R
128 AL67 - Alarma alta presión circ. 2 R
129 AL03 - Alarma monitor de fase R
130 AL10 - Alarma sonda averiada salida evap. 1 R
131 AL09 - Alarma sonda averiada entrada evap. 1 R
134 AL13 - Alarma sonda averiada salida recuperación 1 R
135 AL12 - Alarma sonda averiada entrada recuperación 1 R
136 AL05 - Alarma sonda averiada alta pres. circ. 1 R
137 AL07 - Alarma sonda averiada baja pres. circ. 1 R
138 AL06 - Alarma sonda averiada alta pres. circ. 2 R
139 AL08 - Alarma sonda averiada baja pres. circ. 2 R
140 AL16 - Alarma sonda averiada temperatura exterior R
141 AL48 - Alarma sonda averiada temp. gas impelente 1 R
142 AL49 - Alarma sonda averiada temp. gas impelente 2 R
143 AL17 - Alarma sonda averiada temp. líquido circ. 1 R
144 AL18 - Alarma sonda averiada temp. líquido circ. 2 R
147 AL01 - Alarma batería del reloj descargada R
148 AL02 - Alarma error de memoria pCO R
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aermec BMS pCO5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aermec BMS pCO5 in the language / languages: German as an attachment in your email.

The manual is 0,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info