DECOMPRESSION MODEL
The Decompression Model used by the Atmos Elite is based on the
no decompression multilevel repetitive dive schedules successfully
tested by Dr. Ray Rogers and Dr. Michael Powell. These tests did
not include repetitive dives deeper than 90 feet (27 meters) or decom-
pression dives. Due to the present unavailability of statistical data,
Atmos Elite decompression predictions are based on U.S. Navy
theory.
TISSUE COMPARTMENT CONTROL
The Atmos Elite tracks twelve tissue compartments with halftimes
ranging from 5 to 480 minutes. The Nitrogen Bar Graph always dis-
plays the controlling compartment that is the only one important at
that time. Think of the Nitrogen Bar Graph as twelve separate trans-
parent displays laid on top of one another. The compartment that has
filled up fastest is the only one the viewer can see from the top.
At any particular point, one compartment may be absorbing nitrogen,
while another that was previously higher may be off-gassing. Figure
106 illustrates one compartment handing over control to another
compartment at a different depth. This feature of the Decompres-
sion Model is the basis of multilevel diving, one of the most im-
portant contributions the Atmos Elite offers you.
Fig. 106 - Tissue Compartment
Control Hand Over
Display Seen
by the Diver
Tissue
Half-Times
20
40
108


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris Atmos Elite at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris Atmos Elite in the language / languages: English as an attachment in your email.

The manual is 2,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info