618065
6
Zoom out
Zoom in
Previous page
1/56
Next page
6
A300/A300 XT OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7255-r01 (5/14/12)
Fig. 2 - NORM SURF MAIN
Fig. 1 - DIAGNOSTIC
OVERVIEW
The A300 model features FREE Dive mode as well as NORM, TECH, and GAUG modes.
The A300xt model features a Tank Pressure alarm (actuated by an reed switch) for an analog pressure
gauge mounted in the same console as the dive computer module.
NORM mode is intended for the casual diver who plans to use a single gas and does not yet wish to
configure the numerous settings and alarms, many are factory set at predetermined fixed values.
TECH mode allows the user to configure all settings and alarm values using the control buttons or PCI
program, and set up and switch between multiple gasses.
GAUG mode is for those using the units as digital gauges with no Ni-O2 calculations.
FREE mode (A300 only) is for those using the unit for breath hold activities without scuba.
ACTIVATION & DIAGNOSTICS
A momentary press/release of any button will activate the unit. It will not activate at a depth deeper
than 5 FT (1.5 M) or at an Altitude higher than 14,000 feet.
The unit has contacts that will cause it to activate and enter Dive Mode upon descent to 5 FT (1.5 M)
for 5 seconds.
The contacts are the buttons and the pins of the PCI (PC Interface) data port. Conductivity between
any button and any pin (being wet) will satisfy the activation bridge.
Upon wake up, the unit will check for depth once per second. If depth is not sensed within 10 minutes,
it will enter PSM (Power Saver Mode). Once a dive is made, it will continue checking for depth until
the Time to Fly and Time to Desaturate counters reach 0:00 (hr:min), 24 hours post dive max, and the
unit shuts Off.
Immediately following manual (push button) activation (not if by wet activation), all segments of the
LCD are displayed (Fig. 1) followed by a countdown from 8, -, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0 (approx 3
sec). If sensor readings and battery voltage are within tolerance, the NORM Surface Main screen is
displayed (Fig. 2).
If any value is not acceptable, the failure description will flash for 5 seconds for each type failure. If
more than one failure is sensed, the failures will be presented sequentially in the following order.
EEP >> Eeprom error; CAL >> Calibration error; ALT >> higher than 14000 feet or deeper
than 5 feet; BAT >> Battery voltage too low (icon flashing); A-D >> A/d over range
Once the unit is activated, regardless of what mode it is in, it will enter the selected Dive Mode upon
descent to 5 FT (1.5 M) for 5 seconds.
By accessing the Set OP MOD selection (Fig. 3) in the SET group, the Operating Mode can be
changed from NORM to TECH, GAUG, or FREE (A300 only).
Once a mode is selected, operation remains in that mode until changed.
Once a dive is made in GAUG mode, operation locks into GAUG for 24 hours after surfacing.
While the Surface Main screen is displayed, access to other modes and screens is allowed. They will
remain on display for 2 minutes or until a button is pressed to access another mode or screen.
Fig. 3 - TO ACCESS SET
OPERATING MODE
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 in the language / languages: English as an attachment in your email.

The manual is 14,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info