SET EDT ALARM, information includes (Fig. 33):
> SET icon.
> Graphic OFF (or ON) flashing, with Time value (hr:min) last set with wave/clock icon solid.
A (< 2 sec) to step through the selections OFF, ON, and SET.
M (< 2 sec) to step back through the selections.
S (< 2 sec) to save the selection and access Set TLBG Alarm if OFF or ON is saved (if TECH), or revert to Set ALM if OFF or
ON is saved (if NORM), or flash the Time digits if SET is saved.
S (2 sec), if the selection is not changed, to step back to Set Depth Alarm.
2 minutes, or M (2 sec), revert to Main.
If SET is saved and the Time digits are flashing >>
A (hold) to scroll upward through Set Points from 0:10 to 3:00 (hr:min) in :05 increments at 8/sec.
A (< 2 sec) to step upward through the Set Points.
M (< 2 sec) to step back through the Set Points.
S (< 2 sec) to save the Time value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
S (2 sec), if the Set Point is not changed, to step back to Set Depth Alarm.
2 minutes, or M (2 sec), revert to Main.
SET TLBG ALARM (TECH only), information includes (Fig. 34):
> SET icon and graphic TLBG.
> Graphic OFF (or ON) flashing, with TLBG segments last set solid.
A (< 2 sec) to step through the selections OFF, ON, and SET.
M (< 2 sec) to step back through the selections.
S (< 2 sec) to save the selection and access Set DTR Alarm if OFF or ON is saved, or flash the Time digits if SET is saved.
S (2 sec), if the selection is not changed, to step back to Set Depth Alarm.
2 minutes, or M (2 sec), revert to Main.
If SET is saved and the Time digits are flashing >>
A (< 2 sec) to step upward through the Set Points from 14 through 19 segments.
M (< 2 sec) to step back through the Set Points.
S (< 2 sec) to save the TLBG value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
S (2 sec), if the Set Point is not changed, to step back to Set EDT Alarm.
2 minutes, or M (2 sec), revert to Main.
NORM mode has a fixed TLBG alarm that activates at 14 segments (70%).
SET DTR ALARM (TECH only), information includes (Fig. 35):
> SET icon.
> Graphic OFF (or ON) flashing, with Time value (hr:min) last set with wave/clock/profile icon solid.
A (< 2 sec) to step through the selections OFF, ON, and SET.
M (< 2 sec) to step back through the selections.
S (< 2 sec) to save the selection and revert to Set ALM if OFF or ON is saved, or flash the Time digits if SET is saved.
S (2 sec), if the selection is not changed, to step back to Set Depth Alarm.
2 minutes, or M (2 sec), revert to Main.
If SET is saved and the Time digits are flashing >>
A (hold) to scroll upward through Set Points from 0:05 to 0:20 (hr:min) in :01 increments at 8/sec.
A (< 2 sec) to step upward through the Set Points.
M (< 2 sec) to step back through the Set Points.
S (< 2 sec) to save the Time value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
S (2 sec), if the Set Point is not changed, to step back to Set TLBG Alarm.
2 minutes, or M (2 sec), revert to Main.
NORM mode has a fixed DTR alarm that activates at 5 minutes.
NORM/TECH SET UTL (UTILITIES)
Unless noted otherwise, items set in one mode also apply to the other mode. Example: If the Units is set for Metric while in
NORM mode, it can then be set for Imperial while in TECH mode.
SET UTL LEAD-IN, information includes (Fig. 36):
> Graphics Go To UTL with SET icon.
S (< 2 sec) to access Set Water Type if TECH, or Set Units if NORM.
A (< 2 sec) to step forward to Set TME Lead-in.
M (< 2 sec) to step back to Set ALM Lead-in.
2 minutes, or M (2 sec), revert to Main.
Fig. 33 - SET EDT ALARM
Fig. 34 - SET TLBG ALARM
Fig. 35 - SET DTR ALARM
Fig. 36 - SET DEPTH ALARM
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 XT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 XT in the language / languages: English as an attachment in your email.

The manual is 14,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info