618066
10
Zoom out
Zoom in
Previous page
1/56
Next page
10
A300/A300 XT OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7255-r01 (5/14/12)
NORM/TECH SURFACE MODE
The SURF MAIN screen of the mode selected will remain on display for 10 minutes during which time the unit will enter that type
Dive Mode upon descent to 5 FT (1.5 M) for 5 seconds.
The unit will enter Post Dive Surface Mode for that Mode upon ascent to 2 FT (0.6 M) for 1 second and display the Surface Main
with the Surface Mode (clock/wave) icon flashing.
Access to SURF ALT screens is allowed during the first 10 minutes with access to other surface modes/screens blocked until
10 minutes elapse.
Exception is for Violations.
When the 10 minute post dive surface Interval time has elapsed, access to other Surface modes/screens is allowed. If
another 10 minutes of no action elapses, operation will enter PSM.
NORM/TECH SURFACE SEQUENCE
Sequence >> SURF MAIN >> ALT 1 > ALT 2 > ALT 3 > FLY/DESAT > PLAN > LOG > SET > HIST > ID.
A (< 2 sec) to step forward through the Surface sequence.
A (hold) to scroll forward through the Surface sequence (4/sec).
M (< 2 sec) to step back through the Surface sequence.
S (< 2 sec) to access selections.
S (2 sec) to step back from a selection to the previous selection or sequence item.
M (2 sec), or if no button is pressed during a period of 2 minutes, to revert to SURF MAIN*.
S (press) to activate the Smartglo Backlight.
*ALTs revert to the Main after 10 seconds of no button action.
- - - - - - - - - -
Some of the descriptions that follow only apply to TECH mode.
Some are also shared by GAUG and FREE modes, which will be referenced back in those sections.
NORM/TECH SURF MAIN, information includes (Fig. 7, 8):
> SI (hr:min) with clock/wave icon; if no dive yet, this is time since activation.
> Dive number with # icon; that operating period, up to 24 (0 if no dive made yet).
> Graphic NOR or TEC (operating mode).
> Battery icon, if voltage is low.
> CF icon, if set On.
> Z+ or DSAT icon, the algorithm selected.
> Gas 1 (tank) icon; start gas, default gas 10 minutes after a dive.
> NX icon, if FO2 is set for Nitrox.
> TLBG with icon, if any nitrogen after dives.
A (< 2 sec) to step forward to ALT 1, then step through the Surface Sequence.
A (hold) to scroll forward through the Sequence (4/sec).
M (< 2 sec) to access ID-SN, then step back through the Sequence.
S (press) to activate Smartglo Backlight.
NORM/TECH SURF ALT 1, information includes (Fig. 9):
> Max Depth* with FT (or M) and MAX icons.
> Elapsed Dive Time* (hr:min) with wave/clock icon.
> LAST icon, indicating that data is from the dive previously conducted.
*Dashes if no previous dive.
A (< 2 sec) to step forward to ALT 2.
M (< 2 sec) to step back to Main.
10 sec, or M (2 sec), revert to Main.
S (press) to activate Backlight.
NORM/TECH SURF ALT 2, information includes (Fig. 10):
> Time of Day (hr:min) with AM (or PM) icon, no icon if 24 hour format.
> Temperature with °F (or °C) icon.
> Altitude level graphic, if L2 (to L7), blank if Sea level.
A (< 2 sec) to step forward to ALT 3 (if Nitrox), or access FLY (if Air).
M (< 2 sec) to step back to ALT 1.
10 sec, or M (2 sec), revert to Main.
S (press) to activate Backlight.
Fig. 8 - TECH SURF MAIN
(after dive 2)
Fig. 7 - NORM SURF MAIN
(no dive yet, set for Nitrox)
Fig. 9 - NORM/TECH
SURF ALT 1
Fig. 10 - NORM/TECH
SURF ALT 2
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 XT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 XT in the language / languages: English as an attachment in your email.

The manual is 14,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info