618071
58
Zoom out
Zoom in
Previous page
1/64
Next page
58
A300 CS OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-7287-r04 (8/21/14)

Good (> 2.75 v) >> BATT Icon (green) solid on Surface and Dive Mains. No restrictions surface or dive..
Warning (<= 2.75 v) >> BATT Icon (yellow) solid on Surface and Dive Mains, Battery change recommended. Brightness level automatically limited to
60% maximum.
Alarm (<= 2.50 v) >> BATT Icon (red) ashing on Surface and Dive Mains. Graphics GO UP LOW BATTERY with Up Arrows ashing on Dive Mains,
graphics CHANGE BATTERY (red) ashing on Surface Mains until the unit the shuts off. Must change the Battery.

Warning (<= 2.75 v) >> graphic BATT LOW (yellow) solid on BATT, TMT STATUS screen, Battery change recommended.
Alarm (<= 2.50 v) >> graphic TMTx LOW BATTERY (red) alternating with graphic NORM (or GAUG, or FREE) on Surface Main. Change the Battery.
Alarm (<= 2.50 v) >> graphic BATT LOW (red) ashing on BATT, TMT STATUS screen. Change the Battery.

Out of the water >> between 20 °F and 140 °F (-6 and 60 °C).
In the water >> between 28 °F and 95 °F (-2 and 35 °C).

 segments
• No Deco Normal zone 1 to 6 (green)
• No Deco Caution zone 7 to 9 (yellow)
• Decompression zone 10 (red)
 60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments FPM MPM segments FPM MPM
0 0 - 10 0 - 3 0 0 - 20 0 - 6
Normal zone (green) 1 11 - 15 3.5 - 4.5 1 21 - 30 6.5 - 9
Normal zone (green) 2 16 - 20 5 - 6 2 31 - 40 9.5 - 12
Normal zone (green) 3 21 - 25 6.5 - 7.5 3 41 - 50 12.5 - 15
Caution zone (yellow) 4 26 - 30 8 - 9 4 51 - 60 15.5 - 18
Too Fast zone (red) 5 (all ash) > 30 > 9 5 (all ash) > 60 > 18
 Range: Resolution:
Time of Day 0:00 to 23:59 hr:min 1 minute
PC/Mac Countdown Timer 2:00 to 0:00 min:sec 1 second
Altitude Level Sea, EL-2 to EL-7 1 (level)
Time to Fly 23:50 to 0:00 hr:min 1 minute
Time to Desaturate 23:50 to 0:00 hr:min 1 minute
Temperature 0 to 99°F (-18 to 60°C) 1°F (C)
Depth, Max Depth (display) 0 to 330 FT (100 M) 1 FT (0.1 M )
Tank Pressure 0 to 5000 PSI (345 BAR) 5 PSI (1 BAR)
NORM, GAUG Surface Interval 0:00 to 23:59 hr:min 1 minute
NORM, GAUG Dive Number 0 to 24 1 (dive)
NORM, GAUG Log Entry Number 0 to 99 1 (dive)
NORM, GAUG Elapsed Dive Time 0:00 to 9:59 hr:min 1 minute
NORM Dive Time Remaining 0:00 to 9:59 hr:min 1 minute
NORM, GAUG Air Time Remaining 0 to 99 min 1 minute
FO2 Set Point (Gas 1, 2, 3, 4) Air, 21 to 100 % 1 %
PO2 (current value) 0.00 to 5.00 ATA .01 ATA
O2 Saturation 0 to 100 % 1 %
No Deco Deep Stop Time 2:00 to 0:00 min:sec 1 second
No Deco Safety Stop Time 5:00 to 0:00 min:sec 1 second
No Deco Safety Stop Run Timer 0:00 to 9:59 min:sec 1 second
GAUG Dive Run Timer 0:00 to 9:59 min:sec 1 second
0:10 to 9:59 hr:min 1 minute
Deco Stop Time 0:00 to 9:59 hr:min 1 minute
Deco Total Ascent Time 0:00 to 9:59 hr:min 1 minute
Violation Countdown Timer 23:50 to 0:00 hr:min 1 minute
SPECIFICATIONS (CONTINUED)
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aeris A300 CS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aeris A300 CS in the language / languages: English as an attachment in your email.

The manual is 7,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info