For the Professional
English
2. Installation instructions
2.1 Provisions and regulations
This unit are not suitable for rooms which are subjects to a fire or explosion risk caused by chemicals,
dust, gases or vapours. In workshops or other areas in which the odour of waste gases, oil, petrol, etc.
might occur, or in which work is carried out involving solvents and chemicals, there is a risk of sustained
odour burdens being engendered, and possibly of dirt contamination occurring.
See 1.3 Safety instructions!
The unit may only be fitted with the hanging brackets (7) on a vertical wall which is temperature resistant to
at least 80 °C.
The minimum distances from adjacent objects must be observed
A
.
All electrical connection and installation work is to be carried out in accordance with the I.E.E Regulations, the
provisions of the appropriate electricity supply companies, and the relevant national and regional provisions.
The unit must not be fitted nor positioned directly beneath an electrical wall socket.
The appliance should be installed such that the plug is still accessible.
The unit rating plate is to be noted. The stated voltage must correspond to the mains voltage
If the mains connection cable is changed, this may only be replaced with original AEG spare parts by a quali-
fied installer.
2.2 Unit installation
2.2.1 Fitting the feet
B
The feet (6), including securing screws, are supplied with the unit as standard.
Insert the feet with the guide bars - of variable size - into the side sections at the bottom, and screw tightly.
When doing this, note that in the case of the right-hand foot (6a), the mains connection cable is fed through
the channel in the foot.
2.2.2 Wall mounting
C
(only possible without the feet fitted)
The following action should be taken to secure the unit:
Fix the hanging brackets (7) vertically to the wall. Use suitable securing materials (screws, dowels etc.), de-
pendant on the type of wall.
Observe the minimum distance from the floor!
hang the unit onto the hanging brackets using the vertical recesses in the rear panel of the unit;
using a screwdriver, turn the retaining clips (at the top of the hanging bracket) clockwise into the unit - the
unit is then secured against unintentional removal.
2.3 Electrical connection
Electrical connection can only be made to an a.c. 230V ~ 50 Hz supply.
For the purpose of connection, an earthed socket or unit connection box for permanent connection should be
installed at the side of the heating unit, at least 10 cm away from it.
2.4 Handover
Explain the functions of the unit to the user. Draw his or her attention to the safety instructions, in particular.
Hand the operating and installation instructions to the user.
3. Guarantee
For guarantees please refer to the pespective terms and conditions of supply for your country.
The installation, electrical connection and first operation of this appliance should be carried out by a qualified
installer.
The company does not accept liability for failure of any goods supplied which accor-dance with the
manufacturer‘s instructions.
3.1 Environment and recycling
Recycling of obselete appliances
Appliances with this label must not be disposed off with the general waste. They must be collected separately
and disposed off according to local regulations.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AEG SK 204 T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AEG SK 204 T in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info