34
What to do if...
Symptom Possible Cause Remedy
The food is too warm.
Temperature is not proper-
ly adjusted.
Please look in the “Initial
Start Up” section.
Door was open for an
extended period.
A large quantity of warm
food was placed in the
appliance within the last
24 hours.
The appliance is near a
heat source.
Do not leave the door open
any longer than necessary.
Turn the thermostat knob
to a colder setting tem-
porarily.
Please look in the
“Installation location” section.
Light bulb is defective.
Interior lighting does not
work.
Please look in the “Changing
the light bulb” section.
Heavy build up of frost,
possibly also on the door
seal.
Door seal is not airtight
(possibly after reversing
the door).
Carefully warm the leaking
sections of the door seal
with a hair dryer (on a
cool setting). At the same
time shape the warmed
door seal by hand such
that it sits correctly.
The compressor does not
start immediately after
changing the temperature
setting.
This is normal, no error has
occurred.
Water in the bottom of
the cabinet.
Water drain hole is
blocked.
See the “Cleaning and
Care” section.
The compressor starts after
a period of time.
Changing the light bulb
Warning! There is a risk of electric shocks! Before changing the light
bulb, switch off the appliance and unplug it, or disconnect from the
mains supply.
Light bulb data: 220-240 V, max. 25 W
☞
1. To switch off the appliance, turn the thermostat knob to position "0".
2. Unplug the mains plug.