11
As the colours of the wires in the mains lead of this appliance may
not correspond with the coloured markings identifying the terminals
in your plug, proceed as follows:
1.The wire coloured green and yellow must be connected to the ter-
minal marked with the letter „E“ or by the earth symbol or
coloured green and yellow.
2.The wire coloured blue must be connected to the terminal “N” or
coloured black.
3.The wire coloured brown must be connected to the terminal marked
“L” or coloured red.
4.Upon completion there must be no cut, or stray strands of wire pre-
sent and the cord clamp must be secure over the outer sheath.
Warning! A cut-off plug inserted into a 13 amp socket is a serious
safety (shock) hazard. Ensure that the cut-off plug is disposed of
safety.
Plug socket
The plug socket necessary for
connection of your appliance to the
electricity supply should be
positioned so that it is possible
to pull out the appliance plug.
If your appliance is installed under a
continuous worktop, the plug socket
should be provided as shown.
A concealed spur socket requires 10
A/16 A fusing.
If the socket is not accessible once the appliance is built in, the elec-
trical installation must include suitable means of isolating the appli-
ance from the mains (e.g. fuse, cut-out, current trip or similar with a
minimum contact separation of 3 mm).